NSN 6515-01-167-6634 AK05800, AK-05800 , 01-167-6634
Product Details | CARDIOVASCULAR CATHETERIZATION KIT
6515-01-167-6634 It consists of a catheter and other items which may include needles, dilators, syringe and a spring guide wire. Designed for infusion of multiple solutions, and venous pressure monitoring and blood sampling.
Part Alternates: AK05800, AK-05800 , 6515-01-167-6634, 01-167-6634, 6515011676634, 011676634
Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
65 | 03 DEC 1983 | 01-167-6634 | 45631 ( CATHETERIZATION KIT, CARDIOVASCULAR ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6515-01-167-6634
Related Products | NSN 6515-01-167-6634
Technical Data | NSN 6515-01-167-6634
Characteristic | Specifications |
---|---|
NONSUPPLY ITEMS AND QUANTITIES | CATHETER,IINDWELLING 18 GAGE 2-1/2 IN.,1; DRAPE,FENESTRATED,1; NEEDLE,18 GAGE,2-1/2 IN. LONG,1; NEEDLE,22 GAGE,2-1/2 IN. LONG,1; NEEDLE,25 GAGE,5/8-1 IN. LONG,1; SCALPEL,NO. 11 BLADE,1; SHEATH,8.5 FR POLYTETRAFLUOROETHYLENE 5 IN.,1; SPONGE,2 BY 2 IN.,2; SPONGE,4 BY 4 IN.,5; SPONGE,PREP,2; SUTURE,1; SYRINGE,3 ML,1; SYRINGE,5 ML,1; TRAY,1; WIRE,SPRING GUIDE .035 IN. DIA 17-3/4 IN.,1 |
SPECIAL FEATURES | STERILE; DISPOSABLE; RADIOPAQUE; METAL COMPONENTS FABRICATED OF CRES STEEL |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | CATHETERIZATION KIT CARDIO 8.5FR RADIOPAQUE CRS STERILE DISP |
Restrictions/Controls & Freight Information | NSN 6515-01-167-6634
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 056680 | DENTAL/MEDICAL/SURG INST R MACHINE |
Less than car load rating | ||
Less than truck load rating | F | 150.0 |
Water commodity Code | 651 | unknown |
Originating Activity Code | KX | Defense Supply Center Philadelphia Philiadelphia, PA 19101 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | M | Medical supplies, equipment, samples records, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6515-01-167-6634
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | C | Medical/Dental Materiel |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 03 | Not-Potency-Dated |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | J | PILFERAGE - PILFERAGE CONTROLS MAY BE DESIGNATED BY THE CODING ACTIVITY TO ITEMS CODED U (UNCLASSIFIED) BY RECORDING THE ITEM TO J. |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9L | Navy-owned stocks of defense medical material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | J | PILFERAGE - PILFERAGE CONTROLS MAY BE DESIGNATED BY THE CODING ACTIVITY TO ITEMS CODED U (UNCLASSIFIED) BY RECORDING THE ITEM TO J. |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |