NSN 6515-01-025-8839 922 W/PROVISIONING, 922WPROVISIONING, 01-025-8839
Product Details | INTRAVENOUS INFUSION PUMP
6515-01-025-8839 A portable, volumetric, electric or battery operated item designed to be used for fluid administration therapy. It may also be used with other intravenous delivery systems.
Part Alternates: 922 W/PROVISIONING, 922WPROVISIONING, 6515-01-025-8839, 01-025-8839, 6515010258839, 010258839
Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
65 | 11 AUG 1976 | 01-025-8839 | 45742 ( PUMP, INTRAVENOUS INFUSION ) |
Cross Reference | NSN 6515-01-025-8839
Part Number | Cage Code | Manufacturer |
---|---|---|
922 W/PROVISIONING | 58682 | IMED CORP |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6515-01-025-8839
Related Products | NSN 6515-01-025-8839
Technical Data | NSN 6515-01-025-8839
Characteristic | Specifications |
---|---|
VOLTAGE IN VOLTS | 6.0 |
PORTABILITY | PORTABLE |
SPECIAL FEATURES | VOLUMETRIC; BATTERY OPERATED; BATTERY OPER 40 HOURS AT 125 ML PER HR OUT-PUT ON SINGLE CHARGE; MAY BE RECHARGED FROM 5 WATT,115 V,60 HZ,AC WHILE PUMP IS OPER; FLOW ADJ FROM 1 TO 299 ML PER HR IN 1 ML INCR; CAPABLE OF DELIVERING BOTH CLEAR AND OPAQUE FLUIDS; W/AUDIBLE AND VISIBLE AIR-IN-LINE ALARM; VISIBLE LOW BATTERY ALARM OPER 1 HR PRIOR TO REQUIRED RECHARGE,OCCLUSION ALARM INDICATING OCCLUDED TUBING OR CLOGGED FILTER AND AUDIBLE INFUSION COMPLETION ALARM |
III EXTERIOR CONTAINER QUANTITY | 1 |
III UNIT OF ISSUE WEIGHT | 14.00 POUNDS |
III EXTERIOR CONTAINER WEIGHT | 14.00 POUNDS |
III UNIT OF ISSUE CUBE | 0.398 CUBIC FEET |
III EXTERIOR CONTAINER CUBIC MEASURE | 0.397 CUBIC FEET |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | PUMP INTRAVENOUS INFUSION PRTBLE VOLUMETRIC BATTERY OPERATED 6V |
Restrictions/Controls & Freight Information | NSN 6515-01-025-8839
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 056680 | DENTAL/MEDICAL/SURG INST R MACHINE |
Less than car load rating | ||
Less than truck load rating | F | 150.0 |
Water commodity Code | 651 | unknown |
Originating Activity Code | KX | Defense Supply Center Philadelphia Philiadelphia, PA 19101 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | M | Medical supplies, equipment, samples records, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6515-01-025-8839
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | C | Medical/Dental Materiel |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 03 | Not-Potency-Dated |
Accounting Requirements Code | N | Nonexpendable item. An item of Army property coded with an ARC of?N?in the AMDF. Nonexpendable items require property book accountability after issue from the stock record account. Commercial and fabricated items similar to items coded ?N? in the AMDF are considered nonexpendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | O | If condemned or economically unserviceable, dispose at organizational level. |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9L | Navy-owned stocks of defense medical material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |