Product Details | MEDICINAL NEBULIZER

6515-00-300-4599 A device which employs an air blast in a chamber to vaporize a fluid. The chamber has jets and may have a baffle. The particle size of the mist produced is smaller and more diffused than the jet of spray from an atomizer. It is used in inhalation therapy for respiratory areas in the treatment of asthma where larger sprayed droplets are not satisfactory. Excludes ATOMIZER, MEDICINAL.

Part Alternates: INSPIRON MINI-NEB, INSPIRONMININEB, IT 2220 E, IT2220E, 002220, 2220, 651501C597627, 6515-01-C59-7627, 6515-00-300-4599, 00-300-4599, 6515003004599, 003004599

Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 12 OCT 1973 00-300-4599

Demand History | NSN 6515-00-300-4599

Part Number Request Date QTY Origin
2220 2008-10-295 120 China

Cross Reference | NSN 6515-00-300-4599

Part Number Cage Code Manufacturer
002220 10205 BARD C R INC INSPIRON DIV
2220 10205 BARD C R INC INSPIRON DIV
6515-01-C59-7627 89875 DEFENSE LOGISTICS AGENCY DIRECTORATE OF MEDICAL MATERIEL
INSPIRON MINI-NEB 10205 BARD C R INC INSPIRON DIV
IT 2220 E U6988 SOUTHERN SYRINGE SERVICES LTD

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6515-00-300-4599

Technical Data | NSN 6515-00-300-4599

Characteristic Specifications
MATERIAL AND LOCATION PLASTIC OVERALL
OPERATION METHOD ANY ACCEPTABLE
NASAL TIP NOT PROVIDED
SPECIAL FEATURES INDIVIDUALLY PACKAGED; DISPOSABLE; FOR USE W/MASK AND FACE TENTS,T-BAR; UNIT QTY 50
MANUFACTURERS CODE 10205
DESIGN CONTROL REFERENCE 2220

Restrictions/Controls & Freight Information | NSN 6515-00-300-4599

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information

Management | NSN 6515-00-300-4599

Category Code Description
Cognizance Codes9LNavy-owned stocks of defense medical material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9MDefense Supply Center Philadelphia
Director of Medical Materiel
Philadelphia, PA 19145
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
PG : Package