NSN 6515-00-299-9498 GGC123, 00-299-9498, 002999498
Product Details | EYE CANNULA
6515-00-299-9498 A cannula used for attaching to a syringe filled with air, drugs, or saline solution to be injected into the anterior chamber for irrigation or medication.
Part Alternates: GGC123, 6515-00-299-9498, 00-299-9498, 6515002999498, 002999498
Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
65 | 01 JAN 1963 | 00-299-9498 | 20087 ( CANNULA, EYE ) |
Cross Reference | NSN 6515-00-299-9498
Part Number | Cage Code | Manufacturer |
---|---|---|
GGC123 | 81348 | FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6515-00-299-9498
Related Products | NSN 6515-00-299-9498
Technical Data | NSN 6515-00-299-9498
Characteristic | Specifications |
---|---|
DESIGN DESIGNATION | CASTROVIEJO |
MATERIAL AND LOCATION | BRASS HUB STEEL, CORROSION RESISTING CANNULA |
SURFACE TREATMENT AND LOCATION | NICKEL PLATED HUB CHROMIUM PLATED HUB |
CURVE TO DISTAL TIP LENGTH | 10.000 MILLIMETERS NOMINAL |
OVERALL LENGTH | 43.000 MILLIMETERS NOMINAL |
TIP TYPE | OPEN TOP |
HUB TYPE | LUER LOCK |
SPECIAL FEATURES | FOR CYCLODIALYSIS IN GLAUCOMA AND IRRIGATING THE ANTERIOR CHAMBER OF THE EYE |
III UNIT OF ISSUE WEIGHT | 0.10 POUNDS |
III UNIT OF ISSUE CUBE | 0.005 CUBIC FEET |
MANUFACTURERS CODE | 81348 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | GGC123 |
Restrictions/Controls & Freight Information | NSN 6515-00-299-9498
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 056680 | DENTAL/MEDICAL/SURG INST R MACHINE |
Less than car load rating | ||
Less than truck load rating | F | 150.0 |
Water commodity Code | 651 | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | M | Medical supplies, equipment, samples records, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6515-00-299-9498
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | C | Medical/Dental Materiel |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 03 | Not-Potency-Dated |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | S9M | Defense Supply Center Philadelphia Director of Medical Materiel Philadelphia, PA 19145 |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9L | Navy-owned stocks of defense medical material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | S9M | Defense Supply Center Philadelphia Director of Medical Materiel Philadelphia, PA 19145 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |