Product Details | HEMOSTATIC FORCEPS

6515-00-299-8323 Excludes FORCEPS, SERREFINE.

Part Alternates: 6515-00-299-8323, 00-299-8323, 6515002998323, 002998323

Medical, Dental, and Veterinary Equipment and Supplies | Medical and Surgical Instruments, Equipment, and Supplies

Supply Group (FSG) NSN Assign. NIIN
65 01 JAN 1963 00-299-8323

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6515-00-299-8323

Technical Data | NSN 6515-00-299-8323

Characteristic Specifications
DESIGN DESIGNATION POTTS-DUCTUS
MATERIAL AND LOCATION STEEL CORROSION RESISTING OVERALL
SHAPE ANGULAR
JAW TYPE STRAIGHT
JAW GRASPING METHOD SERRATED
JAW LENGTH 1.000 INCHES NOMINAL
GRIP TYPE FINGER RING
COMPRESSION RETAINING METHOD RATCH-PAWL
JOINT TYPE BOX LOCK
OVERALL LENGTH 7.250 INCHES MINIMUM AND 7.750 INCHES MAXIMUM

Restrictions/Controls & Freight Information | NSN 6515-00-299-8323

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 056680 DENTAL/MEDICAL/SURG INST R MACHINE
Less than car load rating F 150
Less than truck load rating F 150.0
Water commodity Code 651 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity M Medical supplies, equipment, samples records, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6515-00-299-8323

Category Code Description
Cognizance Codes9LNavy-owned stocks of defense medical material
Naval Inventory Control Point, Mechanicsburg
Source of SupplyS9MDefense Supply Center Philadelphia
Director of Medical Materiel
Philadelphia, PA 19145
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
B
EA : Each