Product Details | IMMUNE IN MALTOSE INJECTION GLOBULIN

6505-01-301-8166 00001016505000000

Part Alternates: NDC00026064625, NDC00026-0646-25, NDC00161064025, NDC00161-0640-25, 6505-01-301-8166, 01-301-8166, 6505013018166, 013018166

Medical, Dental, and Veterinary Equipment and Supplies | Drugs and Biologicals

Supply Group (FSG) NSN Assign. NIIN
65 03 JUN 1989 01-301-8166

Cross Reference | NSN 6505-01-301-8166

Part Number Cage Code Manufacturer
NDC00026-0646-25 13521 BAYER PHARMACEUTICALS CORPORATION
NDC00026-0646-25 389N7 TALECRIS BIOTHERAPEUTICS HOLDINGS CORP.
NDC00161-0640-25 93702 CUTTER LABORATORIES INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6505-01-301-8166

Technical Data | NSN 6505-01-301-8166

Characteristic Specifications
IMMEDIATE CONTAINER TYPE VIAL
QUANTITY WITHIN EACH IMMEDIATE CONTAINER 250.0ML
SPECIAL FEATURES 5 PCT GLOBULIN IN 10 PCT MALTOSE; 50MG OF IMMUNE GLOBULIN PER ML; VIAL W/HANGING DEVICE; PACKAGED TOGETHER W/INTRAVENOUS ADMINISTRATION SET
III EXTERIOR CONTAINER QUANTITY 12
III UNIT OF ISSUE WEIGHT 1.42 POUNDS
III UNIT OF ISSUE CUBE 0.1563 CUBIC FEET
III EXTERIOR CONTAINER CUBIC MEASURE 0.875 CUBIC FEET
III PROTECTIVE STORAGE FEATURE REQUIRES REFRIGERATION BETWEEN 2 DEG TO 8 DEG C AND SUBJECT TO DAMAGE BY FREEZING
III PART NAME ASSIGNED BY CONTROLLING AGENCY GLOBULIN IMMUNE IN MALTOSE INJECTION WITH HANGING DEVICE 250ML

Restrictions/Controls & Freight Information | NSN 6505-01-301-8166

Category Code Description
Shelf-Life Code:S60 months
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information

Management | NSN 6505-01-301-8166

Category Code Description
Materiel Category and Inventory ManagerC Medical/Dental Materiel
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group01Type 1 (Non-Extendable) Potency- Dated Item
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life CodeM24 months
Category Code Description
Stores Account Code1Marine Corps Stock Fund Account Item.
Combat Essentiality Code3Critical for Health and Safety of Personnel. Those parts and components that are required for the health and safety of personnel, and which do not fit the definition of Code 5 or 6 items.
Materiel Management CodeBAll CommoditiesDefense Logistics Agency, (DLA,)
Echelon Management Code2ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled.
Physical Category Code1Bin
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDMU.S. Marine Corps
Service OrganizationMU.S. Marine Corps
ReparabilityZNonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code.
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life CodeM24 months
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life CodeM24 months