Product Details | ICE DETECTOR

6350-01-469-9056 A device designed to detect icing conditions and provide an ice warning signal when the ice accretion reaches a preset level. The device may also transmit an electrical signal which can be used to control operation of the ice protection system.20363400033Aircraft Alarm and Signal Systems63500059Miscellaneous Alarm, Signal, and Security Detection Systems66600040Meteorological Instruments and Apparatus

Part Alternates: DPR002, DS-2B, DS2, DS-2, DS2B, 10511002, 1051-1002, 6350-01-469-9056, 01-469-9056, 6350014699056, 014699056

Alarm, Signal and Security Detection Systems | Miscellaneous Alarm, Signal, and Security Detection Systems

Supply Group (FSG) NSN Assign. NIIN
63 30 NOV 1999 01-469-9056

Cross Reference | NSN 6350-01-469-9056

Part Number Cage Code Manufacturer
1051-1002 ZBD53 GIGASAT ASIA PACIFIC PTY LTD
DPR002 1GD22 GENERAL DYNAMICS SATCOM TECHNOLOGIES, INC.
DS-2 0RYR2 AUTOMATED SYSTEMS ENGINEERING, INC DBA ASE
DS-2B 0RYR2 AUTOMATED SYSTEMS ENGINEERING, INC DBA ASE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6350-01-469-9056

Technical Data | NSN 6350-01-469-9056

Characteristic Specifications
MEDIA DETECTED ICE
ELECTRICAL POWER SOURCE RELATIONSHIP OPERATING
AC VOLTAGE RATING 100.0 VOLTS MINIMUM AND 240.0 VOLTS MAXIMUM
FREQUENCY RATING 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
ALTERNATING CURRENT RATING IN AMPS 30.0
SPECIFIC USAGE DESIGN SENSES AMBIENT AIR TEMPERATURE AND PRECIPITATION FOR DEICING AND SNOW MELTING APPLICATIONS
DESIGN TYPE NONTRIPOD MOUNTING
SPECIAL FEATURES OVERALL DIMENSIONS ARE 4.750 IN. BY 7.000 IN. BY 2.750 IN. NOMINAL; OPERATING TEMPERATURE IS MINUS 40.0 TO PLUS 185.0 DEG. F; SUPPLY POWER IS FIELD SELECTABLE, 100.0 TO 120.0 VAC AND 200.0 TO 240.0 VAC AT 15 WATTS PEAK POWER CONSUMPTION; FIELD SELECTABLE TRIGGER TEMPERATURE FROM 34.0 TO 44.0 DEG. F; LOAD CONTACT CAPACITY IS 30.0 AMPS AT 277.0 VAC WITH 100,000 OPERATIONS MINIMUM AT FULL LOAD; MONITOR CONTACT CAPACITY IS 24 VDC/VAC, 400.0 MILLIAMPS, 10.0 WATTS TOTAL; UNIT IS HOUSED IN TWO GANG UL/CSA APPROVED PVC ENCLOSURE WITH NEMA4/IP 66 RATING; ENVIRONMENTALLY SEALED FRONT PANEL CONTROL SWITCH ALLOWS SELECTION OF MANUAL, AUTOMATIC, AND STANDBY/RESET OPTIONS; ELECTRONICSARE ACCESSED BY REMOVING FOUR FRONT COVER SCREWS; UNIT MAY BE MOUNTED BY ATTACHING MOUNTING HUB TO RIGID 0.500 IN. OR 0.750 IN. DIA. CONDUIT, OR BY INSTALLING SCREWS THROUGH FOUR MOUNTING TABS PROVIDED
III UNPACKAGED UNIT WEIGHT 2.000 POUNDS

Restrictions/Controls & Freight Information | NSN 6350-01-469-9056

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information