NSN 6340-00-115-0701 SCD189915, SCD1-899-15, 189915
Product Details | ALARM CONTROL
6340-00-115-0701 An automatic electrical, electromechanical, or electronic device which generates and/or controls the energy which actuates electrical alarms such as bells, horns, sirens, buzzers, lights, and which does not in itself contain the actual alarm. If complete with alarm, the device takes the name of the type of alarm, such as ALARM (as modified).20263400033Aircraft Alarm and Signal Systems63500059Miscellaneous Alarm, Signal, and Security Detection Systems
Part Alternates: SCD189915, SCD1-899-15, 189915, 1-899-15, 6340-00-115-0701, 00-115-0701, 6340001150701, 001150701
Alarm, Signal and Security Detection Systems | Aircraft Alarm and Signal Systems
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
63 | 13 SEP 1968 | 00-115-0701 | 00910 ( CONTROL, ALARM ) |
Demand History | NSN 6340-00-115-0701
Part Number | Request Date | QTY | Origin |
---|---|---|---|
1-899-15 | 2024-11-312 | 29 | DIBBS |
1-899-15 | 2024-11-312 | 15 | DIBBS |
1-899-15 | 2024-10-298 | 15 | DIBBS |
1-899-15 | 2024-10-291 | 15 | DIBBS |
1-899-15 | 2024-07-200 | 29 | DIBBS |
1-899-15 | 2024-04-114 | 108 | DIBBS |
1-899-15 | 2024-04-94 | 89 | DIBBS |
1-899-15 | 2024-03-86 | 89 | DIBBS |
1-899-15 | 2021-09-245 | 2 | |
6340-00-115-0701 | 2019-12-339 | 2 | Canada |
6340-00-115-0701 | 2019-07-205 | 1 | AE |
6340-00-115-0701 | 2018-04-93 | 16 | DIBBS |
6340-00-115-0701 | 2013-12-346 | 16 | DIBBS |
6340-00-115-0701 | 2013-08-238 | 1 | DIBBS-RFPs |
6340-00-115-0701 | 2013-07-207 | 1 | DIBBS-RFPs |
6340-00-115-0701 | 2011-12-342 | 138 | DIBBS |
6340-00-115-0701 | 2011-05-132 | 79 | DIBBS |
189915 | 2011-01-11 | 10 | US |
6340-00-115-0701 | 2010-10-300 | 67 | DIBBS |
189915 | 2010-06-179 | 2 | Indonesia |
6340-00-115-0701 | 2010-05-139 | 68 | DIBBS |
189915 | 2010-04-113 | 1 | Singapore |
6340-00-115-0701 | 2010-02-41 | 74 | DIBBS |
6340-00-115-0701 | 2010-01-29 | 22 | DIBBS |
6340-00-115-0701 | 2009-10-303 | 97 | DIBBS |
6340-00-115-0701 | 2009-10-299 | 100 | US |
6340-00-115-0701 | 2009-10-295 | 36 | DIBBS |
6340-00-115-0701 | 2009-09-266 | 47 | DIBBS |
189915 | 2009-09-251 | 2 | US |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6340-00-115-0701
Related Products | NSN 6340-00-115-0701
Technical Data | NSN 6340-00-115-0701
Characteristic | Specifications |
---|---|
POWER SOURCE | SELF-CONTAINED |
MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
INDICATION METHOD | TRANSMITTING BELL |
TERMINAL TYPE AND QUANTITY | 3 WIRE LEAD |
TERMINAL LOCATION | BOTTOM |
CASE MATERIAL | STEEL, STAINLESS |
INCLOSURE TYPE | ENCAPSULATED |
MAXIMUM OVERALL LENGTH | 2.100 INCHES |
MAXIMUM OVERALL WIDTH | 0.900 INCHES |
MAXIMUM OVERALL HEIGHT | 0.520 INCHES |
SENSING ELEMENT TYPE AND LOCATION | ANEROID CELL REMOTE |
OPERATING TEMP RANGE | -100.0 TO 400.0 DEG FAHRENHEIT |
MOUNTING METHOD | BRACKET |
FEATURES PROVIDED | WARNING INDICATOR |
SPECIAL FEATURES | FLEXIBLE LEADS MS18001 OR EQUIVALENT NO. 18 AWG,3 LEADS,RED,YELLOW,BLUE TWISTED,120.0 IN. LONG MIN |
MANUFACTURERS CODE | 08748 |
DESIGN CONTROL REFERENCE | 1-899-15 |
Restrictions/Controls & Freight Information | NSN 6340-00-115-0701
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061480 | CONTROLLERS/PARTS NOI O/T PLASTIC |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 658 | unknown |
Originating Activity Code | CT | U.S. Army Aviation and Missile Command (AIR) Redstone Arsenal, AL 35898-5230 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6340-00-115-0701
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | J | Ground Forces Support Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Materiel Management Aggregation Code | SX | SX:AF SICA RESIDUAL MMAC-OC-ALC |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |