NSN 6240-00-883-8481 Z139R19, Z139R1-9, 696401
Product Details | GLOW LAMP
6240-00-883-8481 An item in which a gas is ionized to produce light energy of low persistence. It may include internal current limiting resistor.
Part Alternates: Z139R19, Z139R1-9, 696401, 6240-00-883-8481, 00-883-8481, 6240008838481, 008838481
Lighting Fixtures and Lamps | Electric Lamps
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
62 | 17 NOV 1967 | 00-883-8481 | 05758 ( LAMP, GLOW ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6240-00-883-8481
Related Products | NSN 6240-00-883-8481
Technical Data | NSN 6240-00-883-8481
Characteristic | Specifications |
---|---|
BASE STYLE | A96 WIRE LEADS, DOWN |
WIRE LEAD LENGTH | 1.000 INCHES NOMINAL |
BULB STYLE | B25 T |
OVERALL LENGTH | 1.060 INCHES MAXIMUM |
FILLING GAS TYPE | NEON |
LIGHT INTENSITY LEVEL | NOT RATED |
CIRCUIT VOLTAGE RATING IN VOLTS | NOT RATED |
GAS STRIKING VOLTAGE RATING IN VOLTS AND CURRENT TYPE | 139.0 DC NOMINAL 1ST VOLTAGE |
WATTAGE RATING | NOT RATED |
MANUFACTURERS CODE | 71744 |
DESIGN CONTROL REFERENCE | Z139R1-9 |
Restrictions/Controls & Freight Information | NSN 6240-00-883-8481
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 109700 | LAMP OR LIGHTING FIXTURES |
Less than car load rating | W | Rating Variable |
Less than truck load rating | W | Rating Variable |
Water commodity Code | 761 | unknown |
Originating Activity Code | CX | Defense Supply Center Richmond Richmond, VA 23297-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |