Product Details | ELECTRICAL SPECIAL PURPOSE CABLE ASSEMBLY

6150-01-470-6829 A definite continuous length of CABLE, SPECIAL PURPOSE, ELECTRICAL, having one or more ends processed or terminated in fittings which provide for connection to other items. Excludes items having branches or forks. Excludes LEAD, TEST and CABLE AND CONDUIT ASSEMBLY, ELECTRICAL.20611350043Fuzing and Firing Devices, Nuclear Ordnance11900057Specialized Test and Handling Equipment, Nuclear Ordnance132500004935000059950057Cable, Cord, and Wire Assemblies: Communication Equipment61500055Miscellaneous Electric Power and Distribution Equipment

Part Alternates: 2216726, 2216726001, 2216726-001, 6150-01-470-6829, 01-470-6829, 6150014706829, 014706829

Electric Wire, and Power and Distribution Equipment | Miscellaneous Electric Power and Distribution Equipment

Supply Group (FSG) NSN Assign. NIIN
61 05 JAN 2000 01-470-6829

Drawings & Photos | NSN 6150-01-470-6829


Cross Reference | NSN 6150-01-470-6829

Part Number Cage Code Manufacturer
2216726 12436 BAE SYSTEMS NATIONAL SECURITY SOLUTIONS INC.
2216726-001 12436 BAE SYSTEMS NATIONAL SECURITY SOLUTIONS INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6150-01-470-6829

Technical Data | NSN 6150-01-470-6829

Characteristic Specifications
CONDUCTOR QUANTITY 16
ACCESSORY WIRE TYPE AND QUANTITY 8 GROUND AND 2 DRAIN
MATERIAL COPPER CORE CONDUCTOR ALL CONDUCTORS
ROUND CONDUCTOR SIZE 26 AWG ALL CONDUCTORS
OVERALL LENGTH 38.000 INCHES
CROSS-SECTIONAL SHAPE STYLE 6 ROUND
TERMINATION TYPE CONNECTOR 1ST END ALL CONDUCTORS COUPLING 2ND END ALL CONDUCTORS
SPECIAL FEATURES 26AWG ALL CONDUCTORS AND GROUND WIRES, 24AWG ALL DRAIN WIRES - STRANDED (19X36)
SPECIFICATION/STANDARD DATA 96906-MIL-STD-454 GOVERNMENT STANDARD AND 81349-MIL-M-81531 GOVERNMENT SPECIFICATION AND 81349-MIL-C-3885 GOVERNMENT SPECIFICATION AND 81349-MIL-W-22759/18 GOVERNMENT SPECIFICATION
III PRECIOUS MATERIAL AND LOCATION CONTACT SURFACE OF CONNECTOR GOLD
III END ITEM IDENTIFICATION NHA: CHASSIS ASSEMBLY P/N 2216715, E/I: F-16 AIRCRAFT
III PART NAME ASSIGNED BY CONTROLLING AGENCY CABLE ASSEMBLY,IEEE-488

Restrictions/Controls & Freight Information | NSN 6150-01-470-6829

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:GItem contains gold
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061130 CABLE ASSEMBLY
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 743 unknown
Originating Activity Code CH Defense Supply Center Richmond
Richmond, VA 23297
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6150-01-470-6829

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Materiel Management Aggregation CodeWFSU:F-16 AIR COMBAT FIGHTER
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
AY : Assembly