NSN 6150-00-342-3995 L4709ANDTYPEA1, MILL4709, A1
Product Details | ELECTRICAL LOAD BANK
6150-00-342-3995 A set (bank) of electrical elements that are passive (resistive, inductive, capacitive) or active (motors, batteries). They are usually located adjacent to each other to form a consolidated set of any of these elements or any combination of them. A load bank is used to replace distributed or dispersed load elements contained in a power distribution system or electrical network for the purpose of providing a concentrated load. A load bank contains all the essential electrical characteristics necessary to terminate the circuit and functions in the same manner as the load which it is intended to replace. This description necessarily includes a bank of light bulbs or cone heating elements where energy conversion is primarily in the form of heat although visible radiant energy is the natural result of incandescent heating. Load banks are intended to cover a specific range of characteristics and normally operate at DC or at power frequencies 50, 60, or 400 Hz AC. Load banks may be uninstrumented or complete with integral instrumention and may also be furnished as skid or trailer mounted. Excludes TEST SET, ELECTRICAL (as modified). See also DUMMY LOAD, ELECTRICAL.
Part Alternates: L4709ANDTYPEA1, MILL4709, A1, AAT3, 6150-00-342-3995, 00-342-3995, 6150003423995, 003423995
Electric Wire, and Power and Distribution Equipment | Miscellaneous Electric Power and Distribution Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | 01 JAN 1963 | 00-342-3995 | 33776 ( LOAD BANK, ELECTRICAL ) |
Demand History | NSN 6150-00-342-3995
Part Number | Request Date | QTY | Origin |
---|---|---|---|
A1 | 2015-08-225 | 2 | Poland |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6150-00-342-3995
Technical Data | NSN 6150-00-342-3995
Characteristic | Specifications |
---|---|
TEST TYPE FOR WHICH DESIGNED | INTENDED FOR USE IN TESTING 3-PHASE, 120/208V, 400 HZ AC AIRCRAFT TYPE ALTERNATORS |
ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
AC VOLTAGE RATING | 120.0 VOLTS NOMINAL AND 208.0 VOLTS NOMINAL |
FREQUENCY RATING | 400.0 HERTZ NOMINAL |
PHASE | SINGLE |
INCLOSURE FEATURE | SINGLE ITEM W/HOUSING |
HEIGHT | 52.000 INCHES NOMINAL |
LENGTH | 98.000 INCHES NOMINAL |
WIDTH | 68.000 INCHES NOMINAL |
SPECIAL FEATURES | MOBILE UNIT; CAN BE TOWED; 4 WHEEL TRAILER; GROUND CLEARANCE 9 INCHES; INCLUDES COLLAPSIBLE SHELF, CABLE STORAGE COMPARTMENT; WEATHERPROOF |
III SUPPLEMENTARY FEATURES | MANUFACTURERS NAME: LOAD BANK |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | L4709ANDTYPEA1 |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MILL4709 |
Restrictions/Controls & Freight Information | NSN 6150-00-342-3995
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | Y | Information is in the Hazardous Materials Information System (HMIS) |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061700 | ELEC APPLIANCES/INSTRUMENTS NOI |
Less than car load rating | ||
Less than truck load rating | J | 100.2 |
Water commodity Code | 738 | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Q | Extremely fragile items including delicate instruments. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6150-00-342-3995
Category | Code | Description |
---|---|---|
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Materiel Management Aggregation Code | RH | TG:AUTO TEST EQUIPMENT/AUTO TEST SYSTEMS (ATE/ATS) (FSC RESIDUAL MMAC) |
Budget Code | Y | variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly. |
Source of Supply | FLZ | Warner Robins Air Logistics Center Robins AFB, GA 31098-5609 |
Agency | DF | Department of the Air Force |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | U | AF Equipment Management System (AFEMS) |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |