Product Details | ELECTRICAL POWER CABLE

6145-01-600-5063 Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.202411000006145000000

Part Alternates: 422402, 6145-01-600-5063, 01-600-5063, 6145016005063, 016005063

Electric Wire, and Power and Distribution Equipment | Wire and Cable, Electrical

Supply Group (FSG) NSN Assign. NIIN
61 06 DEC 2011 01-600-5063

Cross Reference | NSN 6145-01-600-5063

Part Number Cage Code Manufacturer
422402 66197 CARLISLE INTERCONNECT TECHNOLOGIES, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6145-01-600-5063

Technical Data | NSN 6145-01-600-5063

Characteristic Specifications
CONDUCTOR FORM SOLID, TUBULAR ALL CONDUCTORS
CONDUCTOR QUANTITY 2
MATERIAL COPPER CORE SHIELD BRAID, METALLIC CABLE
MATERIAL PLASTIC FLUOROCARBON CORE JACKET CABLE
CROSS-SECTIONAL SHAPE STYLE ROUND
MATERIAL COPPER CORE CONDUCTOR ALL CONDUCTORS
MATERIAL PLASTIC FLUOROCARBON CORE PRIMARY INSULATION ALL CONDUCTORS
CROSS SECTION OUTSIDE DIAMETER 0.150 INCHES NOMINAL
SPECIAL FEATURES IMPEDANCE: 70OHMS NOMINAL, CAPACITANCE: 24.5 PF/FT MAX, ATTENUATION: 1MHZ 1.40DB/100FT NOMINAL, BEND RADIUS: 0.75 INCH NOMINAL
PART NAME ASSIGNED BY CONTROLLING AGENCY ARINC 429 DATA BUS CABLE
ROUND CONDUCTOR SIZE 24 AWG ALL CONDUCTORS
SURFACE TREATMENT TIN CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENT TIN CORE SHIELD BRAID, METALLIC CABLE
TEMP RATING -55.0 DEG CELSIUS AND 200.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 6145-01-600-5063

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information