Product Details | ELECTRICAL POWER CABLE

6145-01-566-0791 Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.202411000006145000000

Part Alternates: M2750012ML2T23, M27500-12ML2T23, NEMA WC27500, NEMAWC27500, 6145-01-566-0791, 01-566-0791, 6145015660791, 015660791

Electric Wire, and Power and Distribution Equipment | Wire and Cable, Electrical

Supply Group (FSG) NSN Assign. NIIN
61 19 AUG 2008 01-566-0791

Drawings & Photos | NSN 6145-01-566-0791


Demand History | NSN 6145-01-566-0791

Part Number Request Date QTY Origin
6145-01-566-0791 2023-06-163 2500 DIBBS
6145-01-566-0791 2023-02-36 1500 DIBBS
6145-01-566-0791 2022-12-361 500 DIBBS
6145-01-566-0791 2022-12-347 500 DIBBS
M2750012ML2T23 2020-12-344 1 United States
M2750012ML2T23 2020-12-344 1 United States
6145-01-566-0791 2015-01-20 500 DIBBS
6145-01-566-0791 2010-12-357 1500 DIBBS
6145-01-566-0791 2010-12-337 653 DIBBS
6145-01-566-0791 2010-09-246 828 DIBBS
6145-01-566-0791 2010-06-152 286 DIBBS
6145-01-566-0791 2010-05-133 842 DIBBS

Cross Reference | NSN 6145-01-566-0791

Part Number Cage Code Manufacturer
M27500-12ML2T23 1P787 NATIONAL ELECTRICAL MFRS ASSN DBA NEMA
M27500-12ML2T23 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
NEMA WC27500 1P787 NATIONAL ELECTRICAL MFRS ASSN DBA NEMA

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6145-01-566-0791

Technical Data | NSN 6145-01-566-0791

Characteristic Specifications
CONDUCTOR QUANTITY 2
CONDUCTOR FORM STRANDED ALL CONDUCTORS
MATERIAL COPPER ALLOY 101 CORE CONDUCTOR ALL CONDUCTORS PLASTIC POLYALKENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS COPPER 1ST POSITION SHIELD BRAID, METALLIC CABLE PLASTIC POLYVINYLIDENE FLUORIDE 2ND POSITION JACKET ALL CONDUCTORS PLASTIC POLYVINYLIDENE FLUORIDE 2ND POSITION JACKET CABLE
MATERIAL DOCUMENT AND CLASSIFICATION ASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENT TIN CORE CONDUCTOR ALL CONDUCTORS TIN ALLOY 1ST POSITION COATING CABLE
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION ASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
ROUND CONDUCTOR SIZE 12 AWG ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR 19 ALL CONDUCTORS
VOLTAGE RATING 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLE 6 ROUND
TEMP RATING 150.0 DEG CELSIUS
III END ITEM IDENTIFICATION OCS

Restrictions/Controls & Freight Information | NSN 6145-01-566-0791

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 030310 CABLE OR WIRE
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 743 unknown
Originating Activity Code SX Oklahoma City Air Logistics Center
Tinker AFB, OK 73145-3043
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6145-01-566-0791

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
V
FT : Foot