NSN 6145-01-350-2420 E18C095U, E18C0-9-5U, EC18U095U
Product Details | ELECTRICAL POWER CABLE
6145-01-350-2420 Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.202411000006145000000
Part Alternates: E18C095U, E18C0-9-5U, EC18U095U, EC18U0-9-5U, MIL-C-55021/2, MILC550212, 6145-01-350-2420, 01-350-2420, 6145013502420, 013502420
Electric Wire, and Power and Distribution Equipment | Wire and Cable, Electrical
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | 12 DEC 1991 | 01-350-2420 | 00232 ( CABLE, POWER, ELECTRICAL ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6145-01-350-2420
Technical Data | NSN 6145-01-350-2420
Characteristic | Specifications |
---|---|
CONDUCTOR QUANTITY | 3 |
CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B298 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
SURFACE TREATMENT | SILVER CORE CONDUCTOR ALL CONDUCTORS |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B298 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
ROUND CONDUCTOR SIZE | 18 AWG ALL CONDUCTORS |
STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
STRAND AWG SIZE PER CONDUCTOR | 30 ALL CONDUCTORS |
CONDUCTOR ARRANGEMENT AND QUANTITY | 3 TWISTED TOGETHER W/NO OUTER COVERING |
COLOR | BLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR GREEN 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
CROSS-SECTIONAL SHAPE STYLE | 2 TWIST |
CROSS-SECTIONAL HEIGHT | 0.138 INCHES NOMINAL |
CROSS-SECTIONAL WIDTH | 0.138 INCHES NOMINAL |
TEMP RATING | -65.0 DEG CELSIUS AND 200.0 DEG CELSIUS |
III PRECIOUS MATERIAL | SILVER |
III PRECIOUS MATERIAL AND LOCATION | SURFACE ALL CONDUCTORS SILVER |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | E18C0-9-5U |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-C-55021/2 |
Restrictions/Controls & Freight Information | NSN 6145-01-350-2420
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | S | Item contains silver |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |