NSN 6145-01-157-3486 CO08HOF814SJ0550, CO08HOF814SSJ0765, MILC3432
Product Details | ELECTRICAL POWER CABLE
6145-01-157-3486 Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.202411000006145000000
Part Alternates: CO08HOF814SJ0550, CO08HOF814SSJ0765, MILC3432, MIL-C-3432, 19-512236-3, 19-512381-3, 6145-01-157-3486, 01-157-3486, 6145011573486, 011573486, 195122363, 195123813
Electric Wire, and Power and Distribution Equipment | Wire and Cable, Electrical
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | 04 JUL 1983 | 01-157-3486 | 00232 ( CABLE, POWER, ELECTRICAL ) |
Cross Reference | NSN 6145-01-157-3486
Part Number | Cage Code | Manufacturer |
---|---|---|
19-512236-3 | 04655 | GENERAL DYNAMICS C4 SYSTEMS, INC. |
19-512381-3 | 04655 | GENERAL DYNAMICS C4 SYSTEMS, INC. |
CO-08HOF(8/14)SJ0550 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
CO-08HOF(8/14)SSJ0765 | 71124 | GENERAL CABLE INDUSTRIES, INC. DBA WILLIMANTIC, CT PLANT |
MIL-C-3432 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6145-01-157-3486
Technical Data | NSN 6145-01-157-3486
Characteristic | Specifications |
---|---|
CONDUCTOR QUANTITY | 8 |
CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MATERIAL DOCUMENT AND CLASSIFICATION | QQ-W-343,SOFT FED SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
SURFACE TREATMENT | TIN CORE CONDUCTOR SINGLE CONDUCTOR |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33-63 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR |
ROUND CONDUCTOR SIZE | 14 AWG ALL CONDUCTORS |
STRAND QUANTITY PER CONDUCTOR | 41 SINGLE CONDUCTOR |
STRAND AWG SIZE PER CONDUCTOR | 30 SINGLE CONDUCTOR |
CONDUCTOR ARRANGEMENT AND QUANTITY | 8 SINGLES |
COLOR | BLACK 1ST POSITION JACKET CABLE |
VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
CROSS-SECTIONAL SHAPE STYLE | 6 ROUND |
CROSS SECTION OUTSIDE DIAMETER | 0.550 INCHES NOMINAL |
TEMP RATING | -40.0 DEG CELSIUS AND 75.0 DEG CELSIUS |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | CO-08HOF(8/14)SJ0550 |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-C-3432 |
Restrictions/Controls & Freight Information | NSN 6145-01-157-3486
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 030310 | CABLE OR WIRE |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 743 | unknown |
Originating Activity Code | KZ | Defense Supply Center Philadelphia Philadelphia, PA 19101 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6145-01-157-3486
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Materiel Management Aggregation Code | EH | SX:ELECTRONIC COMPONENTS |
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Price Validation | V | The current standard price has been validated.
|
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
V FT : Foot |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
V FT : Foot |