Product Details | ELECTRICAL POWER CABLE

6145-00-839-3895 Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.202411000006145000000

Part Alternates: E16C990U, E16C9-90U, EC16U990U, EC16U9-90U, MIL-C-55021/2, MILC550212, TEH2XAWG1619ECUVS990, 6145-00-839-3895, 00-839-3895, 6145008393895, 008393895

Electric Wire, and Power and Distribution Equipment | Wire and Cable, Electrical

Supply Group (FSG) NSN Assign. NIIN
61 01 JAN 1962 00-839-3895

Drawings & Photos | NSN 6145-00-839-3895


Demand History | NSN 6145-00-839-3895

Part Number Request Date QTY Origin
6145-00-839-3895 2016-02-49 100 US
EC16U990U 2016-02-39 100 US

Cross Reference | NSN 6145-00-839-3895

Part Number Cage Code Manufacturer
E16C9-90U 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
EC16U9-90U 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-C-55021/2 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
TEH2XAWG16/19/E-CU.VS-9+90 C1934 HEW-KABEL/CDT GMBH & CO. KG

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6145-00-839-3895

Technical Data | NSN 6145-00-839-3895

Characteristic Specifications
CONDUCTOR QUANTITY 2
CONDUCTOR FORM STRANDED ALL CONDUCTORS
MATERIAL COPPER CORE CONDUCTOR ALL CONDUCTORS PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
MATERIAL DOCUMENT AND CLASSIFICATION ASTM B298 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENT SILVER CORE CONDUCTOR ALL CONDUCTORS
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION ASTM B298 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS
ROUND CONDUCTOR SIZE 16 AWG ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR 19 ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR 29 ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY 2 TWISTED TOGETHER W/NO OUTER COVERING
COLOR WHITE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
TRACER COLOR BLACK SINGLE TRACER SECOND CONDUCTOR
VOLTAGE RATING 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLE 2 TWIST
CROSS-SECTIONAL HEIGHT 0.080 INCHES NOMINAL
CROSS-SECTIONAL WIDTH 0.160 INCHES NOMINAL
TEMP RATING -65.0 DEG CELSIUS AND 200.0 DEG CELSIUS
SPECIAL FEATURES PRIMARY INSULATION CONFORMS TO L-P-403 TYPE 3
III PRECIOUS MATERIAL SILVER
III PRECIOUS MATERIAL AND LOCATION SURFACE ALL CONDUCTORS SILVER
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE E16C9-90U
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MIL-C-55021/2

Restrictions/Controls & Freight Information | NSN 6145-00-839-3895

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:SItem contains silver
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 030310 CABLE OR WIRE
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 743 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6145-00-839-3895

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
FT : Foot