NSN 6145-00-835-7106 M16878/4BCB1, M168784BCB1, C15YEAWG287BN
Product Details | ELECTRICAL WIRE
6145-00-835-7106 A single metallic conductor of solid, stranded, or tinsel construction, designed to carry current in an electrical circuit. It may be a bare or insulated, may have metalic covering sheath, shield or and additional jacket. Refers to bulk quantities only. For items that are solid or stranded, insulated or uninsulated, and have the chemical composition specified but no conductivity (electrical properties) see WIRE,(as modified), Includes Litz wire and insulated/uninsulated armored, and ground wire. Excludes BRAID, WIRE; FUSE WIRE; RESISTANCE WIRE and MAGNET WIRE.
Part Alternates: M16878/4BCB1, M168784BCB1, C15YEAWG287BN, E2807/1, E28071, MIL-W-16878/4, MILW168784, TE1XAWG28/7/E-CU.VS-1, TE1XAWG287ECUVS1, TX287361, TX-28-736-1, W287FH1, 28827, 2882-7, 6145-00-835-7106, 00-835-7106, 6145008357106, 008357106
Electric Wire, and Power and Distribution Equipment | Wire and Cable, Electrical
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | 01 JAN 1962 | 00-835-7106 | 00798 ( WIRE, ELECTRICAL ) |
Demand History | NSN 6145-00-835-7106
Part Number | Request Date | QTY | Origin |
---|---|---|---|
MILW168784 | 2008-02-44 | 6000 | United States |
Cross Reference | NSN 6145-00-835-7106
Part Number | Cage Code | Manufacturer |
---|---|---|
2882-7 | 92194 | ALPHA WIRE CORPORATION |
C1 5Y(E)AWG28/7BN | D2773 | DRAKA DEUTSCHLAND GMBH & CO. KG |
E2807/1 | F5688 | AXON CABLE |
M16878/4BCB1 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
MIL-W-16878/4 | 81349 | MILITARY SPECIFICATIONS PROMULGATED BY MILITARY |
TE1XAWG28/7/E-CU.VS-1 | C1934 | HEW-KABEL/CDT GMBH & CO. KG |
TX-28-736-1 | D1426 | ARMATHERM GUENTHEL GMBH |
W287FH1 | 98053 | GENERAL CABLE CO DIV OF GK TECHNOLOGIES INC |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6145-00-835-7106
Technical Data | NSN 6145-00-835-7106
Characteristic | Specifications |
---|---|
CONDUCTOR FORM | STRANDED SINGLE CONDUCTOR |
MATERIAL | COPPER CORE CONDUCTOR SINGLE CONDUCTOR PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR |
MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B298 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR |
SURFACE TREATMENT | SILVER CORE CONDUCTOR SINGLE CONDUCTOR |
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B298 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR SINGLE CONDUCTOR |
ROUND CONDUCTOR SIZE | 28 AWG SINGLE CONDUCTOR |
STRAND QUANTITY PER CONDUCTOR | 7 SINGLE CONDUCTOR |
STRAND AWG SIZE PER CONDUCTOR | 36 SINGLE CONDUCTOR |
COLOR | BROWN 1ST POSITION COVER SINGLE CONDUCTOR |
VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE SINGLE CONDUCTOR |
CROSS-SECTIONAL SHAPE STYLE | 6 ROUND |
CROSS SECTION OUTSIDE DIAMETER | 0.035 INCHES NOMINAL |
TEMP RATING | 200.0 DEG CELSIUS |
SPECIAL FEATURES | PRIMARY INSULATION CONFORMS TO L-P-403 TYPE 3 |
III PRECIOUS MATERIAL | SILVER |
III PRECIOUS MATERIAL AND LOCATION | SURFACE SINGLE CONDUCTOR SILVER |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-W-16878/4 |
MANUFACTURERS CODE | 81349 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M16878/4BCB1 |
Restrictions/Controls & Freight Information | NSN 6145-00-835-7106
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | S | Item contains silver |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 030310 | CABLE OR WIRE |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 743 | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6145-00-835-7106
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | S9I | Defense Industrial Supply Center Philadelphia, PA 19111 |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | A | Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
V FT : Foot |