Product Details | ELECTRICAL POWER CABLE

6145-00-238-7050 Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.202411000006145000000

Part Alternates: JC580, 6145-00-238-7050, 00-238-7050, 6145002387050, 002387050

Electric Wire, and Power and Distribution Equipment | Wire and Cable, Electrical

Supply Group (FSG) NSN Assign. NIIN
61 01 JAN 1963 00-238-7050

Drawings & Photos | NSN 6145-00-238-7050


Demand History | NSN 6145-00-238-7050

Part Number Request Date QTY Origin
JC580 2024-11-309 642 United States
JC580 2015-11-322 60 us

Cross Reference | NSN 6145-00-238-7050

Part Number Cage Code Manufacturer
JC580 81348 FEDERAL SPECIFICATIONS PROMULGATED BY GENERAL SERVICES

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6145-00-238-7050

Technical Data | NSN 6145-00-238-7050

Characteristic Specifications
CONDUCTOR QUANTITY 2
CONDUCTOR FORM STRANDED ALL CONDUCTORS
MATERIAL COPPER CORE CONDUCTOR ALL CONDUCTORS RUBBER NATURAL OR RUBBER SYNTHETIC 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS
ROUND CONDUCTOR SIZE 18 AWG ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR 41 ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR 34 ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY 2 SINGLES
VOLTAGE RATING 300.0 DC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLE 6 ROUND
CROSS SECTION OUTSIDE DIAMETER 0.346 INCHES NOMINAL
TEMP RATING 60.0 DEG CELSIUS
SPECIAL FEATURES 250 FT COIL
NONDEFINITIVE SPEC/STD DATA K TYPE AND NO. 18 AWG SIZE
MANUFACTURERS CODE 81348
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE JC580

Restrictions/Controls & Freight Information | NSN 6145-00-238-7050

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information