Product Details | ELECTRICAL POWER CABLE

6145-00-112-8631 Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 American Wire Gage (0.75 SQUARE MILLIMETERS) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see CABLE ASSEMBLY, POWER, ELECTRICAL. For low voltage aircraft and automotive cable, see CABLE, SPECIAL PURPOSE, ELECTRICAL.202411000006145000000

Part Alternates: CW1282, CW1282B, 6145-00-112-8631, 00-112-8631, 6145001128631, 001128631

Electric Wire, and Power and Distribution Equipment | Wire and Cable, Electrical

Supply Group (FSG) NSN Assign. NIIN
61 01 JAN 1963 00-112-8631

Drawings & Photos | NSN 6145-00-112-8631


Cross Reference | NSN 6145-00-112-8631

Part Number Cage Code Manufacturer
CW1282 24446 GENERAL ELECTRIC CO
CW1282 24457 GENERAL ELECTRIC CO WIRE AND CABLE BUSINESS DEPT
CW1282B 24446 GENERAL ELECTRIC CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6145-00-112-8631

Technical Data | NSN 6145-00-112-8631

Characteristic Specifications
CONDUCTOR QUANTITY 10
CONDUCTOR FORM STRANDED ALL CONDUCTORS
MATERIAL COPPER CORE CONDUCTOR ALL CONDUCTORS RUBBER SYNTHETIC 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS COTTON 1ST POSITION SECONDARY INSULATION CABLE RUBBER CHLOROPRENE CLASS CR 2ND POSITION SECONDARY INSULATION CABLE
SURFACE TREATMENT TIN CORE CONDUCTOR ALL CONDUCTORS
ROUND CONDUCTOR SIZE 16 AWG ALL CONDUCTORS
STRAND QUANTITY PER CONDUCTOR 26 ALL CONDUCTORS
STRAND AWG SIZE PER CONDUCTOR 30 ALL CONDUCTORS
CONDUCTOR ARRANGEMENT AND QUANTITY 10 SINGLES
VOLTAGE RATING 500.0 AC MAXIMUM RATED WORKING VOLTAGE ALL CONDUCTORS
CROSS-SECTIONAL SHAPE STYLE 6 ROUND
CROSS SECTION OUTSIDE DIAMETER 0.795 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 6145-00-112-8631

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 030310 CABLE OR WIRE
Less than car load rating S 60
Less than truck load rating W Rating Variable
Water commodity Code 743 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable