Product Details | STORAGE BATTERY

6140-01-041-0264 A battery, composed of two or more cells forming a single unit, which may or may not be readily separable and which may be efficiently recharged by sending an electric current through the cells in a direction opposite that of the discharging current. The item may be furnished with integral charging facilities. For items which are composed of a single cell see CELL, BATTERY.

Part Alternates: 3CA350AH, 3CA3-50AH, 6140-01-041-0264, 01-041-0264, 6140010410264, 010410264

Electric Wire, and Power and Distribution Equipment | Batteries, Rechargeable

Supply Group (FSG) NSN Assign. NIIN
61 01-041-0264

Demand History | NSN 6140-01-041-0264

Part Number Request Date QTY Origin
6140-01-041-0264 2015-05-135 24 VE

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6140-01-041-0264

Technical Data | NSN 6140-01-041-0264

Characteristic Specifications
BATTERY ELECTROLYTE LEAD ACID
VOLTAGE IN VOLTS 5.25
AMPERE HOUR CAPACITY 50.00
TIME CAPACITY IN HOURS 8.00
DISCHARGE RATE IN AMPS 6.30
DISCHARGE TIME IN MINUTES 69.0
TERMINAL QUANTITY 2
TERMINAL TYPE POST W/BOLT
TERMINAL LOCATION TOP AT EACH END
CELL QUANTITY 3
PLATE MATERIAL ANTIMONY ALLOY
PLATE TYPE POSITIVE
PLATE QUANTITY PER CELL 3
SEPARATOR MATERIAL ANY ACCEPTABLE
OVERALL WIDTH 9.000 INCHES NOMINAL
OVERALL LENGTH 7.000 INCHES NOMINAL
OVERALL HEIGHT 13.400 INCHES NOMINAL
CASE MATERIAL PLASTIC
CASE DESIGN TYPE FILLING PLUG OPENINGS
NONSPILLING FEATURE INCLUDED
CHARGE INDICATOR NOT INCLUDED
ELECTROLYTE LEVEL INDICATOR NOT INCLUDED
FORDING FEATURE NOT INCLUDED
STORAGE/SHIPMENT CONDITION DRY CHARGED
INTEGRAL CHARGING FACILITY NOT INCLUDED

Restrictions/Controls & Freight Information | NSN 6140-01-041-0264

Category Code Description
Hazardous Material Indicator CodeYInformation is in the Hazardous Materials Information System (HMIS)
Category Code Description
No Freight Information