Product Details | ELECTRONIC FREQUENCY CONVERTER

6130-01-606-5911 An electronic device having frequency mixing circuits and an integral oscillator which mixes the incoming frequency(ies) with the oscillator frequency, the resultant frequency(ies) being a combination of the two sources. Includes equipment that performs these functions at either radio or power line frequencies. Excludes items that change frequency by means of rotating equipment or rectifier and switching or keying circuitry.20358950037Miscellaneous Communication Equipment59630018Electronic Modules61300035Converters, Electrical, Nonrotating

Part Alternates: ABM8KUX , 6130-01-606-5911, 01-606-5911, 6130016065911, 016065911

Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Nonrotating

Supply Group (FSG) NSN Assign. NIIN
61 2012143 01-606-5911

Cross Reference | NSN 6130-01-606-5911

Part Number Cage Code Manufacturer
ABM8KUX 5M0Z7 ACTOX CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6130-01-606-5911

Technical Data | NSN 6130-01-606-5911

Characteristic Specifications
III CIRCUIT CONSTRUCTION TYPE SOLID STATE
FREQUENCY PER CHANNEL 13.75 GIGAHERTZ MINIMUM OPERATING CHANNEL AND
AVERAGE LIFE RATING 3.0
OPERATING TEMP RANGE -40.0 TO 55.0 DEG CELSIUS
BASIC SHAPE STYLE RECTANGULAR OR SQUARE
OVERALL LENGTH 6.90 INCHES NOMINAL
OVERALL HEIGHT 3.97 INCHES NOMINAL
OVERALL WIDTH 6.65 INCHES NOMINAL
SPECIAL FEATURES FEED HORN MTG; ROHS COMPLIANT; HIGH PWR EFFIENCT;LOW PWR CONSUMPTION(<65W)
III STORAGE TEMP RANGE -40.0 TO 75.0 DEG CELSIUS
III PART NAME ASSIGNED BY CONTROLLING AGENCY 8W KU-BAND BLK UP CONVERTER

Restrictions/Controls & Freight Information | NSN 6130-01-606-5911

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information