NSN 6130-01-565-5093 V300B28C250AL, V300B28C250BL, 851CN0429
Product Details | STATIC FREQUENCY CONVERTER
6130-01-565-5093 An item utilizing electron tubes, transistors, and/or semiconductor devices forming rectifier and electronic keying or switching circuitry, that is inserted between a load designed to operate at one frequency and a power supply line rated at another frequency. For items performing the same function by heterodyne action at either radio or power line frequencies, see CONVERTER, FREQUENCY, ELECTRONIC. For items that perform this function by means of rotary equipment, see MOTOR-GENERATOR. See also DIVIDER-MULTIPLIER, FREQUENCY; FREQUENCY DIVIDER; FREQUENCY MULTIPLIER and MIXER STAGE, FREQUENCY.20358950037Miscellaneous Communication Equipment59630018Electronic Modules61300035Converters, Electrical, Nonrotating
Part Alternates: V300B28C250AL, V300B28C250BL, 851CN0429, 6130-01-565-5093, 01-565-5093, 6130015655093, 015655093
Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Nonrotating
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | 28 JUL 2008 | 01-565-5093 | 00330 ( CONVERTER, FREQUENCY, STATIC ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6130-01-565-5093
Technical Data | NSN 6130-01-565-5093
Characteristic | Specifications |
---|---|
SPECIAL FEATURES | 28 VDC,250 WATT,RIPPLE & NOISE MAX 250MV,EFFICIENCY TYPICAL 87.4%,LOAD CURRENT MAX 5.36 AMPS |
III END ITEM IDENTIFICATION | SEMI-CONDUCTOR DEVICE,DIODE 13755,76/62 SRGM |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | DC-DC CONVERTER MODULE |
Restrictions/Controls & Freight Information | NSN 6130-01-565-5093
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | B | Munitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.) |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |