NSN 6130-01-559-2593 APC SUA750RM1U, APCSUA750RM1U, SUA750RM1U
Product Details | POWER SUPPLY
6130-01-559-2593 A component which converts available alternating current or direct current electrical power into a form required to operate another component or set. The item may consist of a combination of an INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; with a transformer and rectifier(s) employing electron tubes, semiconductor diode or metallic (dry disc) type components, or the synchronized secondary contact(s) of a VIBRATOR, SELF-RECTIFYING; or may consist of electron tubes, semiconductor diode or metallic (dry disc) type rectifiers and capacitors in transformerless (alternating current-direct current type) circuits which may be of the voltage-multiplier type. The item may incorporate a FILTER, DIRECT CURRENT POWER and provisions for regulation of input and/or output voltage. The item may have special input, output, control or other facilities for applications in specialized environments such as medical, dental or other operations. Excludes battery chargers and rotating machinery types of items, such as motor generators and dynamotors.20461200044Transformers: Distribution and Power Station61300035Converters, Electrical, Nonrotating65150057Medical and Surgical Instruments, Equipment, and Supplies65200043Dental Instruments, Equipment, and Supplies
Part Alternates: APC SUA750RM1U, APCSUA750RM1U, SUA750RM1U, 6130-01-559-2593, 01-559-2593, 6130015592593, 015592593
Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Nonrotating
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | 11 DEC 2007 | 01-559-2593 | 00740 ( POWER SUPPLY ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6130-01-559-2593
Technical Data | NSN 6130-01-559-2593
Characteristic | Specifications |
---|---|
OUTPUT VOLTAGE RATING | 120.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT |
OUTPUT CURRENT RATING | 750.0 DC VOLT-AMPERE NOMINAL SINGLE POWER OUTPUT |
OUTPUT WATTAGE RATING | 480.0 WATTS NOMINAL SINGLE POWER OUTPUT |
OUTPUT WAVEFORM AND CURRENT TYPE | FULL WAVE RECTIFIED SINE WAVE DC SINGLE POWER OUTPUT |
ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
BATTERY FEATURE AND TYPE | RECHARGEABLE LEAD ACID CELL |
BATTERY QUANTITY | 1 |
BATTERY RECOVERY TIME | 2.0 |
OVERALL LENGTH | 26.000 INCHES NOMINAL |
OVERALL WIDTH | 17.000 INCHES NOMINAL |
OVERALL HEIGHT | 1.720 INCHES NOMINAL |
INSTALLATION DESIGN | RACK |
SPECIAL FEATURES | APC SMART UPS,480WATTS,750VA,INPUT 120V,OUTPUT 120V,INTERFACE PORT DB-9 RS0232,SMARTSLOT,USB,RM 1U,CD WITH SOFTWARE,RACK MOUNT BRACKETS AND SUPPORT RAILS,UPS SIGNALING RS232 CABLE,USB CABLE AND USERS MANUAL |
III END ITEM IDENTIFICATION | COMMUNICATIONS MANAGEMENT |
III PART NAME ASSIGNED BY CONTROLLING AGENCY | UNINTERRUPTABLE POWER SUPPLY |
Restrictions/Controls & Freight Information | NSN 6130-01-559-2593
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | Q | Strategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.” |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |