Product Details | POWER SUPPLY

6130-01-137-1936 A component which converts available alternating current or direct current electrical power into a form required to operate another component or set. The item may consist of a combination of an INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; with a transformer and rectifier(s) employing electron tubes, semiconductor diode or metallic (dry disc) type components, or the synchronized secondary contact(s) of a VIBRATOR, SELF-RECTIFYING; or may consist of electron tubes, semiconductor diode or metallic (dry disc) type rectifiers and capacitors in transformerless (alternating current-direct current type) circuits which may be of the voltage-multiplier type. The item may incorporate a FILTER, DIRECT CURRENT POWER and provisions for regulation of input and/or output voltage. The item may have special input, output, control or other facilities for applications in specialized environments such as medical, dental or other operations. Excludes battery chargers and rotating machinery types of items, such as motor generators and dynamotors.20461200044Transformers: Distribution and Power Station61300035Converters, Electrical, Nonrotating65150057Medical and Surgical Instruments, Equipment, and Supplies65200043Dental Instruments, Equipment, and Supplies

Part Alternates: A28NT125, PS-28-1.25-VP, PS28125VP, VA28NT125, 6130-01-137-1936, 01-137-1936, 6130011371936, 011371936

Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Nonrotating

Supply Group (FSG) NSN Assign. NIIN
61 22 AUG 1982 01-137-1936

Demand History | NSN 6130-01-137-1936

Part Number Request Date QTY Origin
VA28NT125 2019-08-219 8 DIBBS
6130-01-137-1936 2015-04-120 9 DIBBS
6130-01-137-1936 2011-08-237 4 DIBBS
6130-01-137-1936 2011-03-82 8 DIBBS
6130-01-137-1936 2011-01-06 12 DIBBS
6130-01-137-1936 2010-09-246 5 DIBBS
6130-01-137-1936 2010-02-47 9 DIBBS
6130-01-137-1936 2009-08-237 7 DIBBS

Cross Reference | NSN 6130-01-137-1936

Part Number Cage Code Manufacturer
A28NT125 14749 ACOPIAN TECHNICAL COMPANY
PS-28-1.25-VP 4N727 GE AVIATION SYSTEMS LLC DBA GE AVIATION
PS-28-1.25-VP 91379 PEACOCK AEROSPACE INC
VA28NT125 14749 ACOPIAN TECHNICAL COMPANY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6130-01-137-1936

Technical Data | NSN 6130-01-137-1936

Characteristic Specifications
RECTIFICATION METHOD SINGLE PHASE FULL WAVE BRIDGE
OUTPUT VOLTAGE RATING 28.0 DC VOLTS NOMINAL SINGLE POWER OUTPUT
OUTPUT CURRENT RATING 1.2 DC AMPERES NOMINAL SINGLE POWER OUTPUT
OUTPUT CONTROL TYPE VOLTAGE ADJUSTMENT SINGLE POWER OUTPUT
OUTPUT CONTROL QUANTITY 1 SINGLE POWER OUTPUT
OUTPUT CONTROL LOCATION FRONT PANEL SINGLE POWER OUTPUT
OUTPUT CONNECTION QUANTITY 2 SINGLE POWER OUTPUT
OUTPUT CONNECTION TYPE TERMINAL STRIP SINGLE POWER OUTPUT
ELECTRICAL POWER SOURCE RELATIONSHIP OPERATING
INPUT VOLTAGE RATING 105.0 AC VOLTS MINIMUM AND 125.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT
INPUT FREQUENCY RATING 50.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
INPUT PHASE SINGLE SINGLE OPERATING POWER RQMT
INPUT CONNECTION TYPE TERMINAL STRIP SINGLE OPERATING POWER RQMT
INPUT CONNECTION QUANTITY 2 SINGLE OPERATING POWER RQMT
VENTILATION DESIGN TYPE AMBIENT AIR
OVERALL LENGTH 9.250 INCHES NOMINAL
OVERALL WIDTH 4.680 INCHES NOMINAL
OVERALL HEIGHT 1.680 INCHES NOMINAL
OPERATING AMBIENT TEMP RANGE -20.0 TO 71.0 DEG CELSIUS
FEATURES PROVIDED VOLTAGE ADJUSTMENT AND EMI FILTER
(NON-CORE DATA) SUPPLEMENTARY FEATURES RECTIFIER TYPE: SEMICONDUCTOR DEVICE

Restrictions/Controls & Freight Information | NSN 6130-01-137-1936

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062900 RECTIFIERS NOI/BATTERY ELIMINATORS
Less than car load rating
Less than truck load rating M 85.0
Water commodity Code 658 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6130-01-137-1936

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Materiel Management Aggregation CodeSXSX:AF SICA RESIDUAL MMAC-OC-ALC
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each