Product Details | STATIC FREQUENCY CONVERTER

6130-00-421-5314 An item utilizing electron tubes, transistors, and/or semiconductor devices forming rectifier and electronic keying or switching circuitry, that is inserted between a load designed to operate at one frequency and a power supply line rated at another frequency. For items performing the same function by heterodyne action at either radio or power line frequencies, see CONVERTER, FREQUENCY, ELECTRONIC. For items that perform this function by means of rotary equipment, see MOTOR-GENERATOR. See also DIVIDER-MULTIPLIER, FREQUENCY; FREQUENCY DIVIDER; FREQUENCY MULTIPLIER and MIXER STAGE, FREQUENCY.20358950037Miscellaneous Communication Equipment59630018Electronic Modules61300035Converters, Electrical, Nonrotating

Part Alternates: PS6266D, PS-62-66D , 62581991, 6258199-1, 6130-00-421-5314, 00-421-5314, 6130004215314, 004215314

Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Nonrotating

Supply Group (FSG) NSN Assign. NIIN
61 16 DEC 1970 00-421-5314

Demand History | NSN 6130-00-421-5314

Part Number Request Date QTY Origin
6130-00-421-5314 2019-08-214 1 US

Cross Reference | NSN 6130-00-421-5314

Part Number Cage Code Manufacturer
6258199-1 03640 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN
PS-62-66D 12175 UNITRON INC
PS-62-66D 3BC99 UNITRON, LP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6130-00-421-5314

Technical Data | NSN 6130-00-421-5314

Characteristic Specifications
OUTPUT FREQUENCY RATING 60.0 HERTZ NOMINAL
FREQUENCY REGULATION PERCENT 1.0
OUTPUT WATTAGE RATING NOT RATED
VOLT-AMPERE RATING 3.5 KILOVOLT-AMPERE NOMINAL
LINE TO LINE AC OUTPUT VOLTAGE RATING 200.0 VOLTS NOMINAL
LINE TO GROUND VOLTAGE 115.0 VOLTS NOMINAL
PHASE SINGLE
ACCURACY IN PERCENT 0.01
AC INPUT VOLTAGE RATING 200.0 VOLTS NOMINAL
INPUT FREQUENCY RATING 400.0 HERTZ NOMINAL
INPUT PHASE THREE
LENGTH 22.000 INCHES NOMINAL
WIDTH 9.000 INCHES NOMINAL
HEIGHT 10.000 INCHES NOMINAL
MOUNTING METHOD PANEL
OVERLOAD PROTECTION PROVIDED
RADIO INTERFERENCE FILTER PROVIDED
COOLING METHOD INTEGRAL BLOWER
MANUFACTURERS CODE 12175
DESIGN CONTROL REFERENCE PS-62-66D

Restrictions/Controls & Freight Information | NSN 6130-00-421-5314

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062900 RECTIFIERS NOI/BATTERY ELIMINATORS
Less than car load rating
Less than truck load rating M 85.0
Water commodity Code 671 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6130-00-421-5314

Category Code Description
Materiel Management Aggregation CodeHYSX:ELECTRICAL CONTROL & DISTRIBUTION EQUIPMENT AIRBORNE ELECTRICAL GENERATORS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplyFHZOklahoma City Air Logistics Center
Tinker AFB, OK 73145-5989
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityTAF Recoverable Assembly Management System (AFRAMS)
Acquisition Advice CodesCSERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes7RAeronautical Depot Level Repairable Spares
Naval Inventory Control Point, Philadelphia
Special Material IDRZASN 30 items TACAMO
Issue Repair, or RequisitionARRepairable item subject to centrally managed rework program at designated sites. Mandatory turn-in of item required except when initial issue or replacement of surveyed item is involved.
Special Material Content9 Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions
Source of SupplyNRPNAVICP-ERP
700 Robbins Avenue
Philadelphia, PA 19111-5098
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
ReparabilityHDepot Level Reparable
Acquisition Advice CodesCSERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Inventory Account CodesA Appropriations Purchase Account item managed for the Coast Guard by the respective Inventory Control Point. An unfunded requisition is required.
Source of SupplyZQCCommanding Officer
Department of Homeland Security
USCG Aviation Logistics Center
1664 Weeksville Road
Elizabeth City, NC 27909
AgencyGPU.S. Coast Guard
Service OrganizationCU.S. Coast Guard
ReparabilityR
Acquisition Advice CodesCSERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each