NSN 6125-01-468-9641 375702, 37-570-2, 01-468-9641
Product Details | MOTOR-GENERATOR
6125-01-468-9641 An item which is an electrical rotating machine combining both motor and generator action. The motor and generator(s) may be contained in the same or separate housings. May include accessories such as bed plate, filters, voltage regulators. Excludes DYNAMOTOR, and items consisting of a servomotor and a tachometer generator.
Part Alternates: 375702, 37-570-2, 6125-01-468-9641, 01-468-9641, 6125014689641, 014689641
Electric Wire, and Power and Distribution Equipment | Converters, Electrical, Rotating
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | 28 OCT 1999 | 01-468-9641 | 00830 ( MOTOR-GENERATOR ) |
Cross Reference | NSN 6125-01-468-9641
Part Number | Cage Code | Manufacturer |
---|---|---|
37-570-2 | 91723 | GEORATOR CORPORATION, THE |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6125-01-468-9641
Related Products | NSN 6125-01-468-9641
Technical Data | NSN 6125-01-468-9641
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 60.000 INCHES |
OVERALL WIDTH | 53.300 INCHES |
OVERALL HEIGHT | 43.400 INCHES |
MOUNTING METHOD | FIXED BASE |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
INCLOSURE FEATURE | DRIPTIGHT |
INCLOSURE SPECIFICATION | NEMA |
CURRENT TYPE | AC OUTPUT |
FREQUENCY IN HERTZ | 60.0 OUTPUT |
PHASE | THREE OUTPUT |
CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | 460.0 LINE TO LINE SINGLE INPUT |
POWER RATING | 80.0 KILOWATTS OUTPUT |
DUTY CYCLE | CONTINUOUS |
COOLING METHOD | AMBIENT AIR |
SPECIAL FEATURES | MOTOR: HORIZONTAL FOOT MTD, DRIP-PROOF, FRAME 405T, 125HP, 3-PHASE, 60HZ, 460V, 1780 RPM; GENERATOR: BRUSHLESS, ROTATING RECTIFIER TYPE, FRAME 431 PLUS, 2 BEARING; RATING OUTPUT: 100KVA, 80KW, 0.8PF, 3-PHASE, 60HZ, 120-208V, 1500RPM |
III END ITEM IDENTIFICATION | 5985-01-384-6750; ANTENNA GROUP |
Restrictions/Controls & Freight Information | NSN 6125-01-468-9641
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 062120 | GENERATORS/MOTORS/PARTS NOI |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 593 | unknown |
Originating Activity Code | CH | Defense Supply Center Richmond Richmond, VA 23297 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6125-01-468-9641
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | A | Item requires special handling or condemnation procedures for specific reasons, such as precious metal content, high dollar value, critical material, or hazardous materiel. Refer to appropriate manuals or directives for specific instructions. |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |