Product Details | POWER SUPPLY

6120-01-470-0634 A component which converts available alternating current or direct current electrical power into a form required to operate another component or set. The item may consist of a combination of an INVERTOR, VIBRATOR; VIBRATOR, INTERRUPTER; VIBRATOR, SELF-RECTIFYING; INVERTOR, POWER, STATIC; with a transformer and rectifier(s) employing electron tubes, semiconductor diode or metallic (dry disc) type components, or the synchronized secondary contact(s) of a VIBRATOR, SELF-RECTIFYING; or may consist of electron tubes, semiconductor diode or metallic (dry disc) type rectifiers and capacitors in transformerless (alternating current-direct current type) circuits which may be of the voltage-multiplier type. The item may incorporate a FILTER, DIRECT CURRENT POWER and provisions for regulation of input and/or output voltage. The item may have special input, output, control or other facilities for applications in specialized environments such as medical, dental or other operations. Excludes battery chargers and rotating machinery types of items, such as motor generators and dynamotors.20461200044Transformers: Distribution and Power Station61300035Converters, Electrical, Nonrotating65150057Medical and Surgical Instruments, Equipment, and Supplies65200043Dental Instruments, Equipment, and Supplies

Part Alternates: 6120-01-470-0634, 01-470-0634, 73-190-0223, 6120014700634, 731900223, 014700634

Electric Wire, and Power and Distribution Equipment | Transformers: Distribution and Power Station

Supply Group (FSG) NSN Assign. NIIN
61 06 DEC 1999 01-470-0634

Cross Reference | NSN 6120-01-470-0634

Part Number Cage Code Manufacturer
73-190-0223 08742 ASTEC AMERICA INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6120-01-470-0634

Technical Data | NSN 6120-01-470-0634

Characteristic Specifications
OUTPUT VOLTAGE RATING 28.0 DC VOLTS NOMINAL 1ST POWER OUTPUT 15.0 DC VOLTS NOMINAL 2ND POWER OUTPUT 15.0 DC VOLTS NOMINAL 3RD POWER OUTPUT 12.0 DC VOLTS NOMINAL 4TH POWER OUTPUT 12.0 DC VOLTS NOMINAL 5TH POWER OUTPUT 5.0 DC VOLTS NOMINAL 6TH POWER OUTPUT
OUTPUT CURRENT RATING 21.4 DC AMPERES NOMINAL 1ST POWER OUTPUT 10.0 DC AMPERES NOMINAL 2ND POWER OUTPUT 10.0 DC AMPERES NOMINAL 3RD POWER OUTPUT 5.0 DC AMPERES NOMINAL 4TH POWER OUTPUT 5.0 DC AMPERES NOMINAL 5TH POWER OUTPUT 5.0 DC AMPERES NOMINAL 6TH POWER OUTPUT
OUTPUT WATTAGE RATING 600.0 WATTS NOMINAL 1ST POWER OUTPUT 250.0 WATTS NOMINAL 2ND POWER OUTPUT 250.0 WATTS NOMINAL 3RD POWER OUTPUT 250.0 WATTS NOMINAL 4TH POWER OUTPUT 250.0 WATTS NOMINAL 5TH POWER OUTPUT 250.0 WATTS NOMINAL 6TH POWER OUTPUT
OUTPUT CONTROL TYPE VOLTAGE ADJUSTMENT MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
OUTPUT CONTROL QUANTITY 6 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
OUTPUT CONTROL LOCATION FRONT PANEL MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
OUTPUT CONNECTION QUANTITY 6 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
OUTPUT CONNECTION TYPE THREADED STUD MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS
ELECTRICAL POWER SOURCE RELATIONSHIP OPERATING
INPUT VOLTAGE RATING 85.0 AC VOLTS MINIMUM AND 264.0 AC VOLTS MAXIMUM SINGLE OPERATING POWER RQMT
INPUT FREQUENCY RATING 47.0 HERTZ MINIMUM AND 440.0 HERTZ MAXIMUM SINGLE OPERATING POWER RQMT
INPUT PHASE SINGLE AND THREE SINGLE OPERATING POWER RQMT
VENTILATION DESIGN TYPE EXTERNAL BLOWER
OVERALL LENGTH 12.210 INCHES NOMINAL
OVERALL WIDTH 7.900 INCHES NOMINAL
OVERALL HEIGHT 5.000 INCHES NOMINAL
OPERATING AMBIENT TEMP RANGE -10.0 TO 50.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 6120-01-470-0634

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information