NSN 6115-01-477-0564 982010, 98-2010, 01-477-0564
Product Details | GENERATOR SET WINTERIZATION KIT
6115-01-477-0564 A group of items which after installation improve the functional efficiency of electrical rotating Generator Sets under cold weather environmental conditions. Included are all electric rotating power generator equipment such as: POWER PLANT, ELECTRIC; POWER PLANT, ELECTRIC, TRAILER MOUNTED; POWER PLANT, UTILITY; and those Generator Sets, regardless of prime power source (i.e., gas engine, diesel engine, turbine engine) or mounting (e.g. skid, wheel, trailer, etc.) which require kits for cold weather operations.
Part Alternates: 982010, 98-2010, 6115-01-477-0564, 01-477-0564, 6115014770564, 014770564
Electric Wire, and Power and Distribution Equipment | Generators and Generator Sets, Electrical
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | 29 JUL 2000 | 01-477-0564 | 32689 ( WINTERIZATION KIT, GENERATOR SET ) |
Cross Reference | NSN 6115-01-477-0564
Part Number | Cage Code | Manufacturer |
---|---|---|
98-2010 | 30554 | DEPARTMENT OF DEFENSE PROJECT MANAGER-MOBILE ELECTRIC POWER |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6115-01-477-0564
Related Products | NSN 6115-01-477-0564
Technical Data | NSN 6115-01-477-0564
Characteristic | Specifications |
---|---|
END ITEM IDENTIFICATION | 10KWGENERATOR |
Restrictions/Controls & Freight Information | NSN 6115-01-477-0564
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |
Management | NSN 6115-01-477-0564
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | G | Communications and Electronics Equipment, Electronics Materiel |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
Specific Group/Generic Code | V | Power Generating Systems |
Weapons Systems/End Item or Homogeneous Group | VR | Gen.sets: 60hz, 5 to 10kw |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | B16 | US Army Communications-Electronics Command and Fort Monmouth Fort Monmouth, NJ 07703-5016 |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | F | If condemned or uneconomically repairable, then dispose at Direct Support (DS) level. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Materiel Management Aggregation Code | TG | TG:AF SICA RESIDUAL MMAC-WR-ALC |
Source of Supply | B16 | US Army Communications-Electronics Command and Fort Monmouth Fort Monmouth, NJ 07703-5016 |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |