NSN 6110-01-468-8566 32AA100E, 01-468-8566, 014688566
Product Details | ELECTRICAL MOTOR THERMAL-OVERLOAD PROTECTOR
6110-01-468-8566 A protective device specifically designed to prevent damage to an electrical motor due to failure of the motor to start, severe overloading of short duration, too frequent starting, high ambient temperature, high or low circuit voltages, failure of ventilation or any combination thereof. It is designed to be either automatically or manually reset. Excludes CIRCUIT BREAKEY; SWITCH (1), THERMOSTATIC; HEATER, THERMAL RELEASE; and RELAY (1), THERMAL.
Part Alternates: 32AA100E, 6110-01-468-8566, 01-468-8566, 6110014688566, 014688566
Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | 25 OCT 1999 | 01-468-8566 | 60869 ( PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR ) |
Demand History | NSN 6110-01-468-8566
Part Number | Request Date | QTY | Origin |
---|---|---|---|
6110-01-468-8566 | 2017-08-243 | 1 | United States |
6110-01-468-8566 | 2017-02-49 | 2 | Philippines |
6110-01-468-8566 | 2012-08-244 | 2 | US |
6110-01-468-8566 | 2012-07-201 | 33 | US |
Cross Reference | NSN 6110-01-468-8566
Part Number | Cage Code | Manufacturer |
---|---|---|
32AA100E | 96214 | RAYTHEON COMPANY DBA RAYTHEON |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6110-01-468-8566
Related Products | NSN 6110-01-468-8566
Technical Data | NSN 6110-01-468-8566
Characteristic | Specifications |
---|---|
CURRENT TYPE | AC |
CURRENT RATING IN AMPS | 2.5 |
VOLTAGE RATING | 120.0 VOLTS NOMINAL AND 240.0 VOLTS MAXIMUM |
OPERATION TYPE | MANUAL |
OVERALL LENGTH | 3.200 INCHES NOMINAL |
OVERALL WIDTH | 1.320 INCHES NOMINAL |
OVERALL HEIGHT | 3.000 INCHES NOMINAL |
SPECIAL FEATURES | ONE CHANNEL; 32AA MARK B J-SERIES SENSORS |
III END ITEM IDENTIFICATION | CHILLER, 125 TON |
Restrictions/Controls & Freight Information | NSN 6110-01-468-8566
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |