Product Details | MAGNETIC CONTACTOR

6110-01-187-3314 An item consisting of contacts, a magnetic core, and a coil with or without inclosure which is used to repeatedly establish and break a circuit. The item does not provide overload protection and is not used in line to control any other electrical controls. Excludes RELAY, ELECTROMAGNETIC and STARTER, MOTOR.l circuit. Exludes RELAY, ELECTRO-MAGNETIC and STARTER, MOTOR.

Part Alternates: IC5181C100C3XX, 6110-01-187-3314, 01-187-3314, 6110011873314, 011873314

Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment

Supply Group (FSG) NSN Assign. NIIN
61 21 AUG 1984 01-187-3314

Demand History | NSN 6110-01-187-3314

Part Number Request Date QTY Origin
IC5181C100C3XX 2024-06-165 3 DIBBS
IC5181C100C3XX 2022-08-234 3 DIBBS
IC5181C100C3XX 2022-08-223 3 DIBBS
IC5181C100C3XX 2022-07-199 10 DIBBS
IC5181C100C3XX 2022-06-181 10 DIBBS
IC5181C100C3XX 2021-07-195 5 DIBBS
IC5181C100C3XX 2020-07-188 3 DIBBS
IC5181C100C3XX 2020-02-44 1 DIBBS
IC5181C100C3XX 2020-01-23 1 DIBBS
IC5181C100C3XX 2020-01-09 1 DIBBS
IC5181C100C3XX 2019-06-171 1 DIBBS
IC5181C100C3XX 2019-02-52 1 DIBBS
6110-01-187-3314 2018-10-284 2 DIBBS
6110-01-187-3314 2014-11-310 4 DIBBS
6110-01-187-3314 2014-02-35 5 DIBBS
6110-01-187-3314 2013-12-342 5 DIBBS
6110-01-187-3314 2013-07-211 3 DIBBS
6110-01-187-3314 2011-07-185 1 DIBBS
6110-01-187-3314 2010-11-333 8 DIBBS
6110-01-187-3314 2010-06-169 1 DIBBS
6110-01-187-3314 2010-03-76 1 DIBBS
6110-01-187-3314 2010-03-69 1 DIBBS

Cross Reference | NSN 6110-01-187-3314

Part Number Cage Code Manufacturer
IC5181C100C3XX 02989 GENERAL ELECTRIC CO GE DRIVE SYSTEMS
IC5181C100C3XX 63743 WARD LEONARD ELECTRIC COMPANY INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6110-01-187-3314

Technical Data | NSN 6110-01-187-3314

Characteristic Specifications
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN DESIGNED PER NEMA STD
SIZE DESIGNATOR 0
OPERATING VOLTAGE CHARACTERISTIC FULL
HORSEPOWER RATING 1.000 AND 2.000
CONTROL TYPE LOCAL
ACTUATION METHOD MAGNETIC
ACTUATOR VOLTAGE 115.0 AC
FREQUENCY IN HERTZ 60.0
CIRCUIT PROTECTION FUSE NOT PROVIDED
PERFORMANCE TYPE AUTOMATIC
DUTY CYCLE CONTINUOUS
AMBIENT TEMP 50.0 DEG CELSIUS
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION NOT RATED
INCLOSURE FEATURE OPEN
OVERALL WIDTH 5.400 INCHES NOMINAL
OVERALL LENGTH 5.600 INCHES NOMINAL
OVERALL HEIGHT 5.160 INCHES NOMINAL
MOUNTING CONFIGURATION FOUR 7/32 IN. DIA HOLES; RECTANGULAR PATTERN 4 IN. BY 4 IN. CENTERS
ACCESSORY NOT INCLUDED

Restrictions/Controls & Freight Information | NSN 6110-01-187-3314

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 590 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6110-01-187-3314

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each