NSN 6110-01-124-5637 C203B4, 11CB3E, 11CB3W
Product Details | MOTOR STARTER
6110-01-124-5637 A device primarily designed to control the supply circuit(s) of a motor in order to accelerate the motor from rest to normal speed. Includes manual starters with overload protection and manual, automatic or semiautomatic starters consisting of combinations of items such as relays, resistors, switches, circuit breakers, etc. Excludes RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (as modified) and RELAY (as modified). For devices, which in addition to starting and stopping, reverse, select and/or regulate the speed of a motor, see CONTROLLER (as modified).
Part Alternates: C203B4, 11CB3E, 11CB3W, 6110-01-124-5637, 01-124-5637, 6110011245637, 011245637
Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | 07 JAN 1982 | 01-124-5637 | 00905 ( STARTER, MOTOR ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6110-01-124-5637
Related Products | NSN 6110-01-124-5637
Technical Data | NSN 6110-01-124-5637
Characteristic | Specifications |
---|---|
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
SIZE DESIGNATOR | M-0 |
OPERATING VOLTAGE CHARACTERISTIC | FULL |
AC VOLTAGE RATING | 115.0 VOLTS MINIMUM AND 575.0 VOLTS MAXIMUM |
FREQUENCY RATING | 60.0 HERTZ NOMINAL |
PHASE | THREE |
HORSEPOWER RATING | 3.000 AND 5.000 |
CONTROL TYPE | LOCAL |
ACTUATION METHOD | MANUAL |
CIRCUIT PROTECTION FUSE | NOT PROVIDED |
PERFORMANCE TYPE | MANUAL |
LOAD PROTECTION TYPE | OVERLOAD AND UNDERVOLTAGE |
DUTY CYCLE | ANY ACCEPTABLE |
AMBIENT TEMP | NOT RATED |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | WATERTIGHT-NEMA TYPE 4 |
INCLOSURE FEATURE | FULLY INCLOSED |
OVERALL WIDTH | 6.250 INCHES NOMINAL |
OVERALL LENGTH | 6.500 INCHES NOMINAL |
OVERALL HEIGHT | 11.125 INCHES NOMINAL |
MOUNTING CONFIGURATION | FOUR MTG HOLES FOR 1/4 IN. DIA SCREWS ON 10-3/8 IN. BY 4-1/8 IN. MTG CTR |
SWITCH FUNCTIONAL POSITIONS | RESET AND START AND STOP |
ACCESSORY | NOT INCLUDED |
Restrictions/Controls & Freight Information | NSN 6110-01-124-5637
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 130395 | STARTERS OR STARTER MOTORS |
Less than car load rating | ||
Less than truck load rating | Q | 70.0 |
Water commodity Code | 593 | unknown |
Originating Activity Code | CX | Defense Supply Center Richmond Richmond, VA 23297-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6110-01-124-5637
Category | Code | Description |
---|---|---|
Budget Code | 9 | General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors. |
Price Validation | N | The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
|
Fund Code | SF | Stock fund applicable to items managed for the Air Force by the respective Inventory Control Point. |
Materiel Management Aggregation Code | SX | SX:AF SICA RESIDUAL MMAC-OC-ALC |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |