Product Details | MAGNETIC CONTACTOR

6110-01-099-6893 An item consisting of contacts, a magnetic core, and a coil with or without inclosure which is used to repeatedly establish and break a circuit. The item does not provide overload protection and is not used in line to control any other electrical controls. Excludes RELAY, ELECTROMAGNETIC and STARTER, MOTOR.l circuit. Exludes RELAY, ELECTRO-MAGNETIC and STARTER, MOTOR.

Part Alternates: R5AC2, 6110-01-099-6893, 01-099-6893, 6110010996893, 010996893

Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment

Supply Group (FSG) NSN Assign. NIIN
61 22 AUG 1980 01-099-6893

Cross Reference | NSN 6110-01-099-6893

Part Number Cage Code Manufacturer
R5AC2 08YR5 AMERICAN ELECTRONIC RESOURCE, INC. DBA AERI
R5AC2 73760 ITT CORPORATION DBA ITT AEROSPACE CONTROLS
R5AC2 73905 JENNINGS TECHNOLOGY COMPANY LLC DBA JENNINGS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6110-01-099-6893

Technical Data | NSN 6110-01-099-6893

Characteristic Specifications
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN NOT DESIGNED PER NEMA STD
OPERATING VOLTAGE CHARACTERISTIC FULL
AC VOLTAGE RATING 120.0 VOLTS NOMINAL
FREQUENCY RATING 60.0 HERTZ NOMINAL
HORSEPOWER RATING 2.000
CONTROL TYPE LOCAL OR REMOTE
ACTUATION METHOD MAGNETIC
ACTUATOR VOLTAGE 120.0 AC
FREQUENCY IN HERTZ 60.0
CIRCUIT PROTECTION FUSE NOT PROVIDED
PERFORMANCE TYPE AUTOMATIC
DUTY CYCLE CONTINUOUS
AMBIENT TEMP NOT RATED
SPEED ADJUSTMENTS SINGLE SPEED
REVERSIBLE FEATURE NOT INCLUDED
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION ANY ACCEPTABLE
INCLOSURE FEATURE OPEN FRAME
OVERALL WIDTH 2.530 INCHES NOMINAL
OVERALL LENGTH 3.360 INCHES NOMINAL
OVERALL HEIGHT 2.500 INCHES NOMINAL
ACCESSORY NOT INCLUDED
MANUFACTURERS CODE 08YR5
DESIGN CONTROL REFERENCE R5AC2

Restrictions/Controls & Freight Information | NSN 6110-01-099-6893

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 590 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6110-01-099-6893

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each