NSN 6110-01-025-6058 CN1EB133, 01-025-6058, 010256058
Product Details | MAGNETIC CONTACTOR
6110-01-025-6058 An item consisting of contacts, a magnetic core, and a coil with or without inclosure which is used to repeatedly establish and break a circuit. The item does not provide overload protection and is not used in line to control any other electrical controls. Excludes RELAY, ELECTROMAGNETIC and STARTER, MOTOR.l circuit. Exludes RELAY, ELECTRO-MAGNETIC and STARTER, MOTOR.
Part Alternates: CN1EB133, 6110-01-025-6058, 01-025-6058, 6110010256058, 010256058
Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | 05 AUG 1976 | 01-025-6058 | 31517 ( CONTACTOR, MAGNETIC ) |
Cross Reference | NSN 6110-01-025-6058
Part Number | Cage Code | Manufacturer |
---|---|---|
CN1EB133 | 37833 | SCHNEIDER CANADA INC |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 6110-01-025-6058
Related Products | NSN 6110-01-025-6058
Technical Data | NSN 6110-01-025-6058
Characteristic | Specifications |
---|---|
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | NOT DESIGNED PER NEMA STD |
AC VOLTAGE RATING | 600.0 VOLTS MAXIMUM |
FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
PHASE | TWO |
AMP SIZE RATING | 40.0 |
HORSEPOWER RATING | 15.000 |
ACTUATION METHOD | MAGNETIC |
ACTUATOR VOLTAGE | 200.0 AC AND 575.0 AC |
FREQUENCY IN HERTZ | 50.0 AND 60.0 |
AMBIENT TEMP | NOT RATED |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | ANY ACCEPTABLE |
INCLOSURE FEATURE | OPEN |
OVERALL WIDTH | 3.870 INCHES NOMINAL |
OVERALL LENGTH | 5.120 INCHES NOMINAL |
OVERALL HEIGHT | 5.000 INCHES NOMINAL |
MOUNTING CONFIGURATION | FOUR 0.250 IN. DIA MTG HOLES ON 4.250 IN. BY 2 IN. MTG CENTERS |
ACCESSORY | NOT INCLUDED |
MANUFACTURERS CODE | 37833 |
DESIGN CONTROL REFERENCE | CN1EB133 |
Restrictions/Controls & Freight Information | NSN 6110-01-025-6058
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 061480 | CONTROLLERS/PARTS NOI O/T PLASTIC |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 658 | unknown |
Originating Activity Code | CX | Defense Supply Center Richmond Richmond, VA 23297-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |