NSN 6110-01-013-9313 A203E221, CR306E123, 8536SEG1208
Product Details | MOTOR STARTER
6110-01-013-9313 A device primarily designed to control the supply circuit(s) of a motor in order to accelerate the motor from rest to normal speed. Includes manual starters with overload protection and manual, automatic or semiautomatic starters consisting of combinations of items such as relays, resistors, switches, circuit breakers, etc. Excludes RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (as modified) and RELAY (as modified). For devices, which in addition to starting and stopping, reverse, select and/or regulate the speed of a motor, see CONTROLLER (as modified).
Part Alternates: A203E221, CR306E123, 8536SEG1208, 8536SEG-1-208, 8536SEG1V08, 6110-01-013-9313, 01-013-9313, 6110010139313, 010139313
Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | 11 DEC 1975 | 01-013-9313 | 00905 ( STARTER, MOTOR ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 6110-01-013-9313
Technical Data | NSN 6110-01-013-9313
Characteristic | Specifications |
---|---|
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
SIZE DESIGNATOR | 3 |
OPERATING VOLTAGE CHARACTERISTIC | FULL |
AC VOLTAGE RATING | 600.0 VOLTS MAXIMUM |
FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
PHASE | THREE |
HORSEPOWER RATING | 30.000 |
CONTROL TYPE | LOCAL |
ACTUATION METHOD | MAGNETIC |
ACTUATOR VOLTAGE | 208.0 AC AND 220.0 AC |
FREQUENCY IN HERTZ | 50.0 AND 60.0 |
PERFORMANCE TYPE | SEMIAUTOMATIC |
LOAD PROTECTION TYPE | OVERLOAD |
DUTY CYCLE | CONTINUOUS |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | GENERAL PURPOSE-NEMA TYPE 1 |
OVERALL WIDTH | 11.438 INCHES NOMINAL |
OVERALL LENGTH | 21.812 INCHES NOMINAL |
OVERALL HEIGHT | 8.125 INCHES NOMINAL |
MOUNTING CONFIGURATION | FOUR 3/8 IN. DIA MTG HOLES ON 18-3/4 IN. BY 8-3/8 IN.MTG CENTERS |
SWITCH FUNCTIONAL POSITIONS | RESET |
Restrictions/Controls & Freight Information | NSN 6110-01-013-9313
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 061480 | CONTROLLERS/PARTS NOI O/T PLASTIC |
Less than car load rating | ||
Less than truck load rating | P | 77.5 |
Water commodity Code | 658 | unknown |
Originating Activity Code | CX | Defense Supply Center Richmond Richmond, VA 23297-5000 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 6110-01-013-9313
Category | Code | Description |
---|---|---|
Price Validation | E | The current standard price is an estimated price.
|
Budget Code | O | 8357X3080:Electronics & Telecommunications Replenishment Spares |
Materiel Management Aggregation Code | UD | TG:U-2 COMMON GROUND STATIONS |
Source of Supply | FZZ | WR-ALC/LX Bldg 350 STRM C 750 3rd Street Robbins AFB, GA 31098-2122 |
Agency | DF | Department of the Air Force |
Service Organization | F | U.S. Air Force |
Reparability | N | Stock Fund (except Munitions) |
Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9G | Navy-owned stocks of defense general material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | S9G | Defense Supply Center Richmond Richmond, VA 23297 |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |