Product Details | FIBER OPTIC MODEM

6030-01-573-1784 A device which accepts optic signals and converts them to electrical or radio frequency. It accommodates voltage and optics and is immune to Electromagnetic Interference (EMI) and Radio Frequency Interference (RFI) that is generated. It connects data terminal equipment to a fiber optic transmission line or network.

Part Alternates: EPCI3300000, EPCI-3300-000, 6030-01-573-1784, 01-573-1784, 6030015731784, 015731784

Fiber Optics Materials, Components, Assemblies, and Accessories | Fiber Optic Devices

Supply Group (FSG) NSN Assign. NIIN
60 10 APR 2009 01-573-1784

Cross Reference | NSN 6030-01-573-1784

Part Number Cage Code Manufacturer
EPCI-3300-000 01VV0 ATTO TECHNOLOGY INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 6030-01-573-1784

Technical Data | NSN 6030-01-573-1784

Characteristic Specifications
SPECIAL FEATURES FIBRE CHANNEL PORTS:1; MAX. TRANSFER RATE:400 MB/SEC; MAX. CABLE LENGTH:300M @ 2-GB AND 500M @ 1-GB; CABLE TYPE:MULTI MODE OPTICAL; CABLE SIZE:50 MICRON; CONNECTOR:DUPLEX LC OPTICAL; THE EXPRESS PCI FC 3300 IS A 2-GB FIBRE CHANNEL TO PCI-X BUS HOST ADAPTER WITH ONE FIXED SHORT WAVE OPTICAL LC CONNECTOR
OVERALL HEIGHT 4.200 INCHES NOMINAL
PART NAME ASSIGNED BY CONTROLLING AGENCY EXPRESS PCI 3300 FIBRE CHANNEL CARD
OVERALL LENGTH 6.521 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 6030-01-573-1784

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information