NSN 5998-01-619-7053 PPC7FEASY5WI, PPC7FE-ASY-5WI , 12545883
Product Details | CIRCUIT CARD ASSEMBLY
5998-01-619-7053 A grouping of two or more physically connected or related electrical an/or electronic parts capable of dissassemblage. Each component of the assemblage must be capable of functioning in accordance with its own item name. Consists of a single PRINTED CIRCUIT BOARD or TERMINAL BOARD upon which are mounted separately manufactured electronic components such as capacitors, inductors, resistors, and the like. It may also include printed electronic components. The item is generally part of a subassembly and cannot be assigned a more definite item name. For items having a complete individual electrical/electronic function, use applicable item name such as AMPLIFIER (as modified); POWER SUPPLY; or the like. For items not having a complete individual electrical/electronic function, see applicable subassembly name, such as AMPLIFIER SUBASSEMBLY; POWER SUPPLY SUBASSEMBLY; or the like. For an assembly of electrical/electronic components mounted on other than a single PRINTED WIRING BOARD, see ELECTRONIC COMPONENTS ASSEMBLY. Excludes PRINTED CIRCUIT BOAR
Part Alternates: PPC7FEASY5WI, PPC7FE-ASY-5WI , 12545883 , 5998-01-619-7053, 01-619-7053, 5998016197053, 016197053
Electrical and Electronic Equipment Components | Electrical and Electronic assemblies, Boards, Cards, and Associated Hardware
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 2013164 | 01-619-7053 | 61638 ( CIRCUIT CARD ASSEMBLY ) |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5998-01-619-7053
Restrictions/Controls & Freight Information | NSN 5998-01-619-7053
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | D | Munitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.) |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |
Management | NSN 5998-01-619-7053
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | M | Ammunition weapons, and tracked combat vehicles weapons, special weapons, chemical and fire control materiel |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 1 | REPARABLE ITEMS (Exclusive of Insurance and Provisioning Items.) This code will be used to identify serviceable or unserviceable items of a durable nature which when unserviceable normally can be repaired economically by depots or lower echelons of maintenance. |
Specific Group/Generic Code | J | Tanks |
Weapons Systems/End Item or Homogeneous Group | JW | Tank, Abrams, M1A1 Unique (FOV) |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | B14 | US Army Armament and Chemical Acquisition and Logistics Activity ATTN: AMSTA-AC Rock Island, IL 61299-6000 |
Agency | DA | Department of the Army |
Service Organization | L | Lead Service - 22 (Repairable) |
Reparability | K | Repairable item. Condenmation and disposal to be performed at contractor facility. |
Acquisition Advice Codes | C | SERVICE/AGENCY-MANAGED (Service/Agency use only.) # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by individual Services supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with Service requisitioning procedures. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |