5996-01-571-9332 An electronic device whose radio frequency input signals control power from a source independent of the input signals, and delivers radio frequency output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It operates at frequencies above 20 kilohertz.202598500005996000000

Part Alternates: AMFW6S0725077545KP1TC, AMFW-6S-07250775-45K-P1-TC, 5996-01-571-9332, 01-571-9332, 5996015719332, 015719332

Electrical and Electronic Equipment Components | Amplifiers

Supply Group (FSG) NSN Assign. NIIN
59 20 FEB 2009 01-571-9332

Cross Reference | NSN 5996-01-571-9332

Part Number Cage Code Manufacturer
AMFW-6S-07250775-45K-P1-TC 33592 MITEQ, INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5996-01-571-9332

Technical Data | NSN 5996-01-571-9332

Characteristic Specifications
FREQUENCY PER CHANNEL 7250.0 MEGAHERTZ MINIMUM OPERATING CHANNEL AND 7750.0 MEGAHERTZ MAXIMUM OPERATING CHANNEL
IMPEDANCE RATING PER CHANNEL 50.000 OHMS OPERATING CHANNEL
SPECIAL FEATURES WAVEGUIDE PACKAGE
OVERALL GAIN 50.0 DECIBELS
OPERATING TEMP RANGE -40.0/+60.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5996-01-571-9332

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description