Product Details | RADIO FREQUENCY AMPLIFIER

5996-01-299-3732 An electronic device whose radio frequency input signals control power from a source independent of the input signals, and delivers radio frequency output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It operates at frequencies above 20 kilohertz.202598500005996000000

Part Alternates: A187046, A1870461, A187046-1, AM109SMA, AM-109-SMA, 8424, 5996-01-299-3732, 01-299-3732, 5996012993732, 012993732

Electrical and Electronic Equipment Components | Amplifiers

Supply Group (FSG) NSN Assign. NIIN
59 30 APR 1989 01-299-3732

Drawings & Photos | NSN 5996-01-299-3732


Demand History | NSN 5996-01-299-3732

Part Number Request Date QTY Origin
8424 2015-05-146 20 United States

Cross Reference | NSN 5996-01-299-3732

Part Number Cage Code Manufacturer
8424 96341 COBHAM ELECTRONIC SYSTEMS INC. DBA COBHAM DEFENSE ELECTRONICS
A187046 13030 LOCKHEED MARTIN SIPPICAN, INC. DBA SIPPICAN USE CAGE CODE 16848 FOR
A187046-1 13030 LOCKHEED MARTIN SIPPICAN, INC. DBA SIPPICAN USE CAGE CODE 16848 FOR
AM-109-SMA 46592 PENSTOCK/MIDWEST INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5996-01-299-3732

Technical Data | NSN 5996-01-299-3732

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
FREQUENCY PER CHANNEL 0.3 MEGAHERTZ MINIMUM OPERATING CHANNEL AND 60.0 MEGAHERTZ MAXIMUM OPERATING CHANNEL
OPERATING CONTROL METHOD AUTOMATIC
CONTROL TYPE REMOTE
AVERAGE LIFE MEASUREMENT NOT RATED
OPERATING TEMP RANGE -10.0 TO 70.0 DEG CELSIUS
EXTERNAL DC OPERATING VOLTAGE IN VOLTS 20.0 NOMINAL SINGLE VOLTAGE
CONNECTION TYPE AND LOCATION RECEPTACLE, COAXIAL BOTTOM AND RECEPTACLE, COAXIAL TOP
CONNECTION CONTACT TYPE AND QUANTITY 2 RECEPTACLE, COAXIAL EXTERNAL
INCLOSURE TYPE ENCASED
ENVIRONMENTAL PROTECTION MOISTURE PROOF AND SHOCK RESISTANT AND VIBRATION
INSTALLATION DESIGN MECHANICAL
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 3.000 INCHES NOMINAL
OVERALL HEIGHT 1.020 INCHES NOMINAL
OVERALL WIDTH 2.000 INCHES NOMINAL
IDENTIFICATION DESIGNATOR A187046-13030
III STORAGE TEMP RANGE -10.0 TO 75.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5996-01-299-3732

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:CMunitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories.
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063035 SETS RADIO/TV AND RELATED ARTICLES
Less than car load rating
Less than truck load rating G 125.0
Water commodity Code 723 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5996-01-299-3732

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each