Product Details | RADIO FREQUENCY AMPLIFIER

5996-01-248-7293 An electronic device whose radio frequency input signals control power from a source independent of the input signals, and delivers radio frequency output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It operates at frequencies above 20 kilohertz.202598500005996000000

Part Alternates: APN/030-3012-59, APN030301259, 6011369002, 6011369-002, 5996-01-248-7293, 01-248-7293, 5996012487293, 012487293

Electrical and Electronic Equipment Components | Amplifiers

Supply Group (FSG) NSN Assign. NIIN
59 30 JAN 1987 01-248-7293

Drawings & Photos | NSN 5996-01-248-7293


Cross Reference | NSN 5996-01-248-7293

Part Number Cage Code Manufacturer
6011369-002 12436 BAE SYSTEMS NATIONAL SECURITY SOLUTIONS INC.
APN/030-3012-59 66087 CTT INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5996-01-248-7293

Technical Data | NSN 5996-01-248-7293

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
FREQUENCY PER CHANNEL 2.000 GIGAHERTZ MINIMUM OPERATING CHANNEL AND 3.000 GIGAHERTZ MAXIMUM OPERATING CHANNEL
IMPEDANCE RATING PER CHANNEL 50.000 OHMS OPERATING CHANNEL
AVERAGE LIFE MEASUREMENT NOT RATED
OPERATING TEMP RANGE -55.0 TO 85.0 DEG CELSIUS
EXTERNAL DC OPERATING VOLTAGE IN VOLTS 12.0 NOMINAL SINGLE VOLTAGE
CONNECTION TYPE AND LOCATION RECEPTACLE, COAXIAL LEFT SIDE AND RECEPTACLE, COAXIAL RIGHT SIDE AND WIRE LEAD TERMINALS RIGHT SIDE
CONNECTION CONTACT TYPE AND QUANTITY 2 RECEPTACLE, COAXIAL EXTERNAL AND 2 WIRE LEAD TERMINALS EXTERNAL
INCLOSURE TYPE ENCASED
INSTALLATION DESIGN MECHANICAL
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 2.840 INCHES MAXIMUM
OVERALL HEIGHT 1.000 INCHES NOMINAL
OVERALL WIDTH 0.320 INCHES MAXIMUM
III SPECIAL MARKINGS SENSITIVE TO ELECTROSTATIC DISCHARGE
III STORAGE TEMP RANGE -65.0 TO 125.0 DEG CELSIUS

Restrictions/Controls & Freight Information | NSN 5996-01-248-7293

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:CMunitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories.
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063035 SETS RADIO/TV AND RELATED ARTICLES
Less than car load rating
Less than truck load rating G 125.0
Water commodity Code 723 unknown
Originating Activity Code TH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5996-01-248-7293

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each