NSN 5996-01-154-1064 8447EOPT010, 01-154-1064, 011541064
Product Details | RADIO FREQUENCY AMPLIFIER
5996-01-154-1064 An electronic device whose radio frequency input signals control power from a source independent of the input signals, and delivers radio frequency output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It operates at frequencies above 20 kilohertz.202598500005996000000
Part Alternates: 8447EOPT010, 5996-01-154-1064, 01-154-1064, 5996011541064, 011541064
Electrical and Electronic Equipment Components | Amplifiers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 20 MAY 1983 | 01-154-1064 | 00446 ( AMPLIFIER, RADIO FREQUENCY ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5996-01-154-1064
Related Products | NSN 5996-01-154-1064
Technical Data | NSN 5996-01-154-1064
Characteristic | Specifications |
---|---|
CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
FREQUENCY PER CHANNEL | 100.0 KILOHERTZ MINIMUM OPERATING CHANNEL AND 1.3 GIGAHERTZ MAXIMUM OPERATING CHANNEL |
OVERALL GAIN | 22.0 DECIBELS |
IMPEDANCE RATING PER CHANNEL | 50.000 OHMS OPERATING CHANNEL |
EXTERNAL AC OPERATING VOLTAGE IN VOLTS | 110.0 MINIMUM SINGLE VOLTAGE AND 230.0 MAXIMUM SINGLE VOLTAGE |
OPERATING AC FREQUENCY IN HERTZ | 48.0 MINIMUM SINGLE VOLTAGE AND 440.0 MAXIMUM SINGLE VOLTAGE |
PHASE | SINGLE |
CONNECTION TYPE AND LOCATION | RECEPTACLE, COAXIAL FRONT |
CONNECTION CONTACT TYPE AND QUANTITY | 2 RECEPTACLE, COAXIAL EXTERNAL |
INCLOSURE TYPE | ENCASED |
INSTALLATION DESIGN | TOP OF CABINET/COUNTER |
BASIC SHAPE STYLE | 1 RECTANGULAR OR SQUARE |
OVERALL LENGTH | 8.500 INCHES NOMINAL |
OVERALL HEIGHT | 3.400 INCHES NOMINAL |
OVERALL WIDTH | 5.100 INCHES NOMINAL |
SPECIAL FEATURES | OPTION 010 PROVIDES TYPE N COAXIAL CONNECTORS FOR INPUT AND OUTPUT |
Restrictions/Controls & Freight Information | NSN 5996-01-154-1064
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 063035 | SETS RADIO/TV AND RELATED ARTICLES |
Less than car load rating | ||
Less than truck load rating | G | 125.0 |
Water commodity Code | 723 | unknown |
Originating Activity Code | ZG | Germany ZH ZJ |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5996-01-154-1064
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |