Product Details | RADIO FREQUENCY AMPLIFIER

5996-01-042-0782 An electronic device whose radio frequency input signals control power from a source independent of the input signals, and delivers radio frequency output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It operates at frequencies above 20 kilohertz.202598500005996000000

Part Alternates: 06-168369-1, 5996-01-042-0782, 01-042-0782, 5996010420782, 061683691, 010420782

Electrical and Electronic Equipment Components | Amplifiers

Supply Group (FSG) NSN Assign. NIIN
59 06 JUN 1977 01-042-0782

Drawings & Photos | NSN 5996-01-042-0782


Demand History | NSN 5996-01-042-0782

Part Number Request Date QTY Origin
5996-01-042-0782 2016-05-133 1 DIBBS
5996-01-042-0782 2012-05-133 1 DIBBS

Cross Reference | NSN 5996-01-042-0782

Part Number Cage Code Manufacturer
06-168369-1 04655 GENERAL DYNAMICS C4 SYSTEMS, INC.
06-168369-1 51128 WILLIAM S GUTTENBERG DBA WILCO ELECTRIC COMPANY
06-168369-1 52340 C-RAN CORP

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5996-01-042-0782

Technical Data | NSN 5996-01-042-0782

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
FREQUENCY PER CHANNEL 121.5 MEGAHERTZ NOMINAL OPERATING CHANNEL
AVERAGE POWER RATING PER CHANNEL 100.0 MILLIWATTS INPUT
OPERATING CONTROL METHOD AUTOMATIC
CONTROL TYPE REMOTE
AVERAGE LIFE MEASUREMENT NOT RATED
OPERATING TEMP RANGE -28.0 TO 65.0 DEG CELSIUS
SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS 15.0
SHOCK PULSE DURATION TIME 11.0 MILLISECONDS
EXTERNAL DC OPERATING VOLTAGE IN VOLTS 10.0 NOMINAL SINGLE VOLTAGE
CONNECTION TYPE AND LOCATION PIN BOTTOM
CONNECTION CONTACT TYPE AND QUANTITY 14 PIN EXTERNAL
INCLOSURE TYPE HERMETICALLY SEALED
ENVIRONMENTAL PROTECTION VIBRATION AND SHOCK RESISTANT
INSTALLATION DESIGN MODULE
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 2.656 INCHES NOMINAL
OVERALL HEIGHT 0.301 INCHES NOMINAL
OVERALL WIDTH 1.600 INCHES NOMINAL
SPECIAL FEATURES USED ON POSEIDON AND TRIDENT SUBMARINES
CRITICALITY CODE JUSTIFICATION FEAT

Restrictions/Controls & Freight Information | NSN 5996-01-042-0782

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:YThe item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063035 SETS RADIO/TV AND RELATED ARTICLES
Less than car load rating
Less than truck load rating G 125.0
Water commodity Code 723 unknown
Originating Activity Code HD Naval Inventory Control Point
Mechanicsburg, PA 17055-0788
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5996-01-042-0782

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Special Material Content2 Electrostatic Discharge (ESD)/Electromagnetic (EM) Sensitive Item
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each