Product Details | DIRECT CURRENT AMPLIFIER

5996-01-040-7013 An electronic device whose input signals control power from a source independent of the input signals and delivers output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It is used for small variations in direct current electrical impulses, and generally employs direct coupling between stages through resistors.

Part Alternates: 13461530, 13-4615-30, 13G461530, 13-G4615-30, 5996-01-040-7013, 01-040-7013, 5996010407013, 010407013

Electrical and Electronic Equipment Components | Amplifiers

Supply Group (FSG) NSN Assign. NIIN
59 12 MAY 1977 01-040-7013

Drawings & Photos | NSN 5996-01-040-7013


Cross Reference | NSN 5996-01-040-7013

Part Number Cage Code Manufacturer
13-4615-30 3SLK7 LDS TEST AND MEASUREMENT LLC
13-4615-30 96795 GOULD INSTRUMENT SYSTEMS INC
13-G4615-30 3SLK7 LDS TEST AND MEASUREMENT LLC
13-G4615-30 96795 GOULD INSTRUMENT SYSTEMS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5996-01-040-7013

Technical Data | NSN 5996-01-040-7013

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
SIGNAL VOLTAGE RATING PER CHANNEL 500.000 VOLTS NOMINAL INPUT
IMPEDANCE RATING PER CHANNEL 50.000 KILOHMS INPUT CHANNEL
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 14.000 INCHES NOMINAL
OVERALL HEIGHT 6.875 INCHES NOMINAL
OVERALL WIDTH 1.125 INCHES NOMINAL
MANUFACTURERS CODE 96795
DESIGN CONTROL REFERENCE 13-4615-30

Restrictions/Controls & Freight Information | NSN 5996-01-040-7013

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063035 SETS RADIO/TV AND RELATED ARTICLES
Less than car load rating D 200
Less than truck load rating G 125.0
Water commodity Code 738 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5996-01-040-7013

Category Code Description
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Materiel Management Aggregation CodeQCTG:ELECTRICAL AND ELECTRONIC PROPERTIES MEASURING AND TESTING
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilityTAF Recoverable Assembly Management System (AFRAMS)
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each