Product Details | RADIO FREQUENCY AMPLIFIER

5996-01-021-1320 An electronic device whose radio frequency input signals control power from a source independent of the input signals, and delivers radio frequency output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It operates at frequencies above 20 kilohertz.202598500005996000000

Part Alternates: WJ5030323, WJ5030-323, WJ5030323PA, WJ-5030-323PA, WJ5030323SP1, WJ-5030-323SP1, 5996-01-021-1320, 01-021-1320, 5996010211320, 010211320

Electrical and Electronic Equipment Components | Amplifiers

Supply Group (FSG) NSN Assign. NIIN
59 09 MAY 1976 01-021-1320

Drawings & Photos | NSN 5996-01-021-1320


Cross Reference | NSN 5996-01-021-1320

Part Number Cage Code Manufacturer
WJ-5030-323PA 14482 WATKINS-JOHNSON CO
WJ-5030-323SP1 14482 WATKINS-JOHNSON CO
WJ5030-323 14482 WATKINS-JOHNSON CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5996-01-021-1320

Technical Data | NSN 5996-01-021-1320

Characteristic Specifications
CIRCUIT CONSTRUCTION TYPE SOLID STATE
FREQUENCY PER CHANNEL 50.0 MEGAHERTZ MINIMUM OPERATING CHANNEL 500.0 MEGAHERTZ MAXIMUM OPERATING CHANNEL
FREQUENCY ADJUSTMENT TYPE CONTINUOUS
INCLOSURE TYPE ENCASED
INSTALLATION DESIGN MECHANICAL
BASIC SHAPE STYLE 1 RECTANGULAR OR SQUARE
OVERALL LENGTH 3.905 INCHES NOMINAL
OVERALL HEIGHT 1.300 INCHES NOMINAL
OVERALL WIDTH 2.525 INCHES NOMINAL
SPECIAL FEATURES PLUS 15.0V EXTERNAL DC OPERATING VOLTAGE
MANUFACTURERS CODE 14482
DESIGN CONTROL REFERENCE WJ-5030-323SP1

Restrictions/Controls & Freight Information | NSN 5996-01-021-1320

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 063035 SETS RADIO/TV AND RELATED ARTICLES
Less than car load rating M 85
Less than truck load rating G 125.0
Water commodity Code 738 unknown
Originating Activity Code SE San Antonio Air Logistics Center
Kelly AFB, TX 78241-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5996-01-021-1320

Category Code Description
Materiel Management Aggregation CodeQCTG:ELECTRICAL AND ELECTRONIC PROPERTIES MEASURING AND TESTING
Price ValidationX The current standard price has been validated and the previous price was erroneous.
  • The item was overpriced and the contractor has refunded the overcharge or DoD activities did not actually pay the previous price. The price paid is within the analyzed acceptable range.
  • If the difference from the previous price exceeds $99.99, or if the price change exceeds 500 percent and the extended value of any affected transaction exceeds $99.99, then reverse-post procedures will apply where the stock fund has overcharged unit O&M Funds. These corrections will be limited to the current fiscal year.
    • ZOP or Standard Price challenges are permissible, but should be supported by adequate justification
Budget CodeY variousO & M:AF centrally procured equipment items. They are separate, primary end items (other than the weapon system itself) needed by a user to perform an assigned mission. They are nonexpendable items (ERRCD NF or ND) which are not consumed in use, and they do not lose their original identity during periods of use by incorporation into, or attachment to another assembly.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationLLead Service - 22 (Repairable)
ReparabilitySAF Equipment Management System (AFEMS)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each