NSN 5996-00-995-6535 5496521003, 549-6521-003, 00-995-6535
Product Details | RADIO FREQUENCY AMPLIFIER
5996-00-995-6535 An electronic device whose radio frequency input signals control power from a source independent of the input signals, and delivers radio frequency output signals of greater amplitude with respect to current and/or voltage. The output signals characteristics are uniformly related to the input signals. It operates at frequencies above 20 kilohertz.202598500005996000000
Part Alternates: 5496521003, 549-6521-003, 5996-00-995-6535, 00-995-6535, 5996009956535, 009956535
Electrical and Electronic Equipment Components | Amplifiers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 01 JAN 1962 | 00-995-6535 | 00446 ( AMPLIFIER, RADIO FREQUENCY ) |
Cross Reference | NSN 5996-00-995-6535
Part Number | Cage Code | Manufacturer |
---|---|---|
549-6521-003 | 13499 | ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5996-00-995-6535
Related Products | NSN 5996-00-995-6535
Technical Data | NSN 5996-00-995-6535
Characteristic | Specifications |
---|---|
CIRCUIT CONSTRUCTION TYPE | SOLID STATE |
FREQUENCY PER CHANNEL | 2.0 MEGAHERTZ MINIMUM OUTPUT CHANNEL 12.0 MEGAHERTZ MAXIMUM OUTPUT CHANNEL |
AVERAGE POWER RATING PER CHANNEL | 4.0 WATTS INPUT |
IMPEDANCE RATING PER CHANNEL | NOT RATED |
OPERATING CONTROL METHOD | AUTOMATIC |
CONTROL TYPE | REMOTE |
AVERAGE LIFE MEASUREMENT | NOT RATED |
EXTERNAL DC OPERATING VOLTAGE IN VOLTS | 24.0 NOMINAL SINGLE VOLTAGE |
INCLOSURE TYPE | OPEN |
INSTALLATION DESIGN | MODULE |
BASIC SHAPE STYLE | 1 RECTANGULAR OR SQUARE |
OVERALL LENGTH | 2.500 INCHES NOMINAL |
OVERALL HEIGHT | 0.375 INCHES NOMINAL |
OVERALL WIDTH | 1.625 INCHES NOMINAL |
IDENTIFICATION DESIGNATOR | 549-6521-003-13499 |
III FSC APPLICATION DATA | RADIO SIGNAL DATA TRANSLATOR,EXCEPT NAVIGATION,NONAIRBORNE |
Restrictions/Controls & Freight Information | NSN 5996-00-995-6535
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | C | Munitions List Item or Commerce Control List Item. Demilitarization required. Remove and/or demilitarize installed key point(s) as prescribed in the Defense Demilitarization Manual, or lethal parts, components and accessories. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
NMF Description | 063035 | SETS RADIO/TV AND RELATED ARTICLES |
Less than car load rating | ||
Less than truck load rating | G | 125.0 |
Water commodity Code | 723 | unknown |
Originating Activity Code | XX | |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5996-00-995-6535
Category | Code | Description |
---|---|---|
Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
Combat Essentiality Code | 6 | Critical Repair Part to a Non-Combat Essential End Item. Those parts or components whose failure in a noncombat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
Materiel Management Code | E | Electronics MaterielDefense Electronics Supply Center (DESC) |
Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
Operational Test Code | 2 | Items of equipment which require the performance of special procedures are not controlled through the MOWASP special handling suspense routine by USMC/Serial Numbers, (except small arms which are controlled by serial numbers but are assigned OTC 2). Normally OTC 2 items of equipments are small arms, engines (except small engines coded SAC-1 which are non-technical), pumps, generators, electronic equipments and major components/subassemblies of weapon systems, etc. Electronic Circuit Cards and other items which have received Level A packing will only be assigned an OTC when an operational test is mandatory prior to issue. |
Physical Category Code | 1 | Bin |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DM | U.S. Marine Corps |
Service Organization | M | U.S. Marine Corps |
Reparability | F | Reparable item. When uneconomically reparable, condemn and dispose at the third echelon level. |
Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
Controlled Item Code | 7 | NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7). |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |