Product Details | ELECTRICAL SPECIAL PURPOSE CABLE ASSEMBLY

5995-01-024-7124 A definite continuous length of CABLE, SPECIAL PURPOSE, ELECTRICAL, having one or more ends processed or terminated in fittings which provide for connection to other items. Excludes items having branches or forks. Excludes LEAD, TEST and CABLE AND CONDUIT ASSEMBLY, ELECTRICAL.20611350043Fuzing and Firing Devices, Nuclear Ordnance11900057Specialized Test and Handling Equipment, Nuclear Ordnance132500004935000059950057Cable, Cord, and Wire Assemblies: Communication Equipment61500055Miscellaneous Electric Power and Distribution Equipment

Part Alternates: 99017030, 9901-7030, 5995-01-024-7124, 01-024-7124, 5995010247124, 010247124

Electrical and Electronic Equipment Components | Cable, Cord, and Wire Assemblies: Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
59 19 JUL 1976 01-024-7124

Drawings & Photos | NSN 5995-01-024-7124


Cross Reference | NSN 5995-01-024-7124

Part Number Cage Code Manufacturer
9901-7030 50664 SYSTEM INDUSTRIES INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5995-01-024-7124

Technical Data | NSN 5995-01-024-7124

Characteristic Specifications
CONDUCTOR QUANTITY 4
CONDUCTOR FORM STRANDED ALL CONDUCTORS
MATERIAL COPPER CORE CONDUCTOR ALL CONDUCTORS PLASTIC 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC 1ST POSITION JACKET CABLE
ROUND CONDUCTOR SIZE 22 AWG ALL CONDUCTORS
STYLE DESIGNATOR 40 INTERNAL AND EXTERNAL CONNECTOR
OVERALL LENGTH 7.500 INCHES
CROSS-SECTIONAL SHAPE STYLE 6 ROUND
TERMINATION TYPE CONNECTOR PLUG 1ST END ALL CONDUCTORS CONNECTOR RECEPTACLE 2ND END ALL CONDUCTORS
TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER 335-0024 1ST END ALL CONDUCTORS 335-0025 2ND END ALL CONDUCTORS
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE 50664 1ST END ALL CONDUCTORS 50664 BOTH ENDS ALL CONDUCTORS
MANUFACTURERS CODE 50664
DESIGN CONTROL REFERENCE 9901-7030

Restrictions/Controls & Freight Information | NSN 5995-01-024-7124

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061130 CABLE ASSEMBLY
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 743 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5995-01-024-7124

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each