NSN 5995-00-984-5246 85341, 00-984-5246, 009845246
Product Details | ELECTRICAL SPECIAL PURPOSE CABLE ASSEMBLY
5995-00-984-5246 A definite continuous length of CABLE, SPECIAL PURPOSE, ELECTRICAL, having one or more ends processed or terminated in fittings which provide for connection to other items. Excludes items having branches or forks. Excludes LEAD, TEST and CABLE AND CONDUIT ASSEMBLY, ELECTRICAL.20611350043Fuzing and Firing Devices, Nuclear Ordnance11900057Specialized Test and Handling Equipment, Nuclear Ordnance132500004935000059950057Cable, Cord, and Wire Assemblies: Communication Equipment61500055Miscellaneous Electric Power and Distribution Equipment
Part Alternates: 85341, 5995-00-984-5246, 00-984-5246, 5995009845246, 009845246
Electrical and Electronic Equipment Components | Cable, Cord, and Wire Assemblies: Communication Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 26 OCT 1966 | 00-984-5246 | 00782 ( CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL ) |
Cross Reference | NSN 5995-00-984-5246
Part Number | Cage Code | Manufacturer |
---|---|---|
85341 | 99592 | RAYTHEON COMPANY DBA RAYTHEON |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5995-00-984-5246
Related Products | NSN 5995-00-984-5246
Technical Data | NSN 5995-00-984-5246
Characteristic | Specifications |
---|---|
CONDUCTOR QUANTITY | 34 |
CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS PLASTIC 1ST POSITION JACKET CABLE |
SURFACE TREATMENT | TIN 1ST POSITION CONDUCTOR ALL CONDUCTORS |
ROUND CONDUCTOR SIZE | 16 AWG ALL CONDUCTORS |
STRAND QUANTITY PER CONDUCTOR | 26 ALL CONDUCTORS |
STRAND AWG SIZE PER CONDUCTOR | 30 ALL CONDUCTORS |
CONDUCTOR ARRANGEMENT AND QUANTITY | 22 SINGLES AND 3 QUADS |
STYLE DESIGNATOR | 33 DUAL INTERNAL ANGLE CONNECTOR |
OVERALL LENGTH | 96.000 INCHES |
CROSS-SECTIONAL SHAPE STYLE | 6 ROUND |
CROSS SECTION OUTSIDE DIAMETER | 1.070 INCHES NOMINAL |
TERMINATION TYPE | CONNECTOR PLUG BOTH ENDS ALL CONDUCTORS |
TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | MS3126F22-55P 1ST END ALL CONDUCTORS MS3126F22-55S 2ND END ALL CONDUCTORS |
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 81349 1ST END ALL CONDUCTORS 81349 BOTH ENDS ALL CONDUCTORS |
III FSC APPLICATION DATA | TEST SET,ELECTRONIC SYSTEMS,EXCEPT SPECIALLY DESIGNED |
MANUFACTURERS CODE | 99592 |
DESIGN CONTROL REFERENCE | 85341 |
Restrictions/Controls & Freight Information | NSN 5995-00-984-5246
Category | Code | Description |
---|---|---|
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | B | Munitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.) |
Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
Precious Metals Indicator Code: | A | Item does not contain precious metal |
Criticality Code: | N | The item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input). |
Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
Category | Code | Description |
---|---|---|
No Freight Information |
Management | NSN 5995-00-984-5246
Category | Code | Description |
---|---|---|
Materiel Category and Inventory Manager | G | Communications and Electronics Equipment, Electronics Materiel |
Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
Specific Group/Generic Code | 0 | Medical Materiel |
Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
Source of Supply | B16 | US Army Communications-Electronics Command and Fort Monmouth Fort Monmouth, NJ 07703-5016 |
Agency | DA | Department of the Army |
Service Organization | A | U.S. Army |
Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |