Product Details | RADIO FREQUENCY CABLE ASSEMBLY

5995-00-467-3884 A definite length of CABLE, RADIO FREQUENCY having one or both ends processed and/or terminated in fittings which provide for connection to other items. Includes multiple cable assemblies in a common jacket or shield. Excludes items having branches or forks and LEAD, TEST. See also CABLE ASSEMBLY, RADIO FREQUENCY, BRANCHED.20211350043Fuzing and Firing Devices, Nuclear Ordnance59950057Cable, Cord, and Wire Assemblies: Communication Equipment

Part Alternates: CG1127BU10FT, 5995-00-467-3884, 00-467-3884, 5995004673884, 004673884

Electrical and Electronic Equipment Components | Cable, Cord, and Wire Assemblies: Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
59 07 JUN 1974 00-467-3884

Drawings & Photos | NSN 5995-00-467-3884


Cross Reference | NSN 5995-00-467-3884

Part Number Cage Code Manufacturer
CG1127BU10FT 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5995-00-467-3884

Technical Data | NSN 5995-00-467-3884

Characteristic Specifications
CONDUCTOR QUANTITY 1
CONDUCTOR FORM STRANDED SINGLE CONDUCTOR
MATERIAL COPPER 1ST POSITION CONDUCTOR SINGLE CONDUCTOR PLASTIC POLYETHYLENE TEREPHTHALATE 1ST POSITION PRIMARY INSULATION SINGLE CONDUCTOR TIN 2ND POSITION CONDUCTOR SINGLE CONDUCTOR COPPER 2ND POSITION SHIELD BRAID, METALLIC SINGLE CONDUCTOR TIN 3RD POSITION COATING SINGLE CONDUCTOR PLASTIC POLYVINYL CHLORIDE 4TH POSITION JACKET SINGLE CONDUCTOR
ROUND CONDUCTOR SIZE 20 AWG SINGLE CONDUCTOR
STRAND QUANTITY PER CONDUCTOR 19 SINGLE CONDUCTOR
STRAND AWG SIZE PER CONDUCTOR 33 SINGLE CONDUCTOR
CONDUCTOR ARRANGEMENT AND QUANTITY 1 COAXIAL
ELECTRICAL RESISTANCE 50.00 OHMS IMPEDANCE
STYLE DESIGNATOR 33 DUAL INTERNAL ANGLE CONNECTOR
OVERALL LENGTH 10.000 FEET
CROSS-SECTIONAL SHAPE STYLE 6 ROUND
CROSS SECTION OUTSIDE DIAMETER 0.195 INCHES NOMINAL
TEMP RATING -40.0 DEG CELSIUS AND 85.0 DEG CELSIUS
TERMINATION TYPE CONNECTOR INTERNAL ANGLE BOTH ENDS SINGLE CONDUCTOR
TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE 81349 BOTH ENDS SINGLE CONDUCTOR
SPECIAL FEATURES RG58C/U CABLE

Restrictions/Controls & Freight Information | NSN 5995-00-467-3884

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061320 COAXIAL TRANSMISSION LINE/FITTINGS
Less than car load rating J 100.2
Less than truck load rating J 100.2
Water commodity Code 658 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable