NSN 5995-00-103-0469 G712309902, G7123-099-02, 00-103-0469
Product Details | ELECTRICAL LEAD
5995-00-103-0469 A definite length of one-conductor electrical wire, wire braid, or other conductive material, except cable or cord, one or both ends of which are processed or terminated. The lead may be of any size or shape, insulated or uninsulated. See also LEAD, TEST and BUS CONDUCTOR. Excludes LEAD, STORAGE BATTERY; LEAD, IGNITION, ENGINE, and items having attached switches, lampholders, suppressors, resistors, and the like.20511350043Fuzing and Firing Devices, Nuclear Ordnance11900057Specialized Test and Handling Equipment, Nuclear Ordnance5995000061500055Miscellaneous Electric Power and Distribution Equipment65150057Medical and Surgical Instruments, Equipment, and Supplies
Part Alternates: G712309902, G7123-099-02, 5995-00-103-0469, 00-103-0469, 5995001030469, 001030469
Electrical and Electronic Equipment Components | Cable, Cord, and Wire Assemblies: Communication Equipment
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 05 JUN 1968 | 00-103-0469 | 04581 ( LEAD, ELECTRICAL ) |
Cross Reference | NSN 5995-00-103-0469
Part Number | Cage Code | Manufacturer |
---|---|---|
G7123-099-02 | 88818 | KEARFOTT CORPORATION DBA KEARFOTT |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5995-00-103-0469
Technical Data | NSN 5995-00-103-0469
Characteristic | Specifications |
---|---|
CONDUCTOR FORM | STRANDED SINGLE CONDUCTOR |
MATERIAL | COPPER CORE CONDUCTOR SINGLE CONDUCTOR |
ROUND CONDUCTOR SIZE | 22 AWG SINGLE CONDUCTOR |
STRAND QUANTITY PER CONDUCTOR | 19 SINGLE CONDUCTOR |
STRAND AWG SIZE PER CONDUCTOR | 34 SINGLE CONDUCTOR |
CROSS-SECTIONAL SHAPE STYLE | 6 ROUND |
CROSS SECTION OUTSIDE DIAMETER | 0.103 INCHES NOMINAL |
TERMINATION TYPE | PROD TERMINAL BOTH ENDS SINGLE CONDUCTOR |
LEAD OVERALL LENGTH | 21.500 INCHES NOMINAL |
MANUFACTURERS CODE | 88818 |
DESIGN CONTROL REFERENCE | G7123-099-02 |
Restrictions/Controls & Freight Information | NSN 5995-00-103-0469
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 062360 | LEADS/LEAD WIRES ELEC ARTICLE ETC |
Less than car load rating | ||
Less than truck load rating | J | 100.2 |
Water commodity Code | 743 | unknown |
Originating Activity Code | KE | Naval ICP Philadelphia, PA 19111 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5995-00-103-0469
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | X | SEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |