Product Details | FIXED ATTENUATOR

5985-01-621-5385 A device for reducing the strength of an alternating current signal by a fixed or predetermined amount, without causing appreciable signal distortion, by maintaining correct impedance match.

Part Alternates: PCAL8, PCAL-8 , 5985-01-621-5385, 01-621-5385, 5985016215385, 016215385

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 2013254 01-621-5385

Cross Reference | NSN 5985-01-621-5385

Part Number Cage Code Manufacturer
PCAL-8 64537 AEROFLEX CONTROL COMPONENTS, INC. DBA AEROFLEX / KDI

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-621-5385

Technical Data | NSN 5985-01-621-5385

Characteristic Specifications
APPLICATION DESIGN TRANSMISSION LINE
INPUT IMPEDANCE RATING IN OHMS 50.0
OUTPUT IMPEDANCE RATING IN OHMS 50.0
FREQUENCY RANGE 8.0 HERTZ MINIMUM AND
RF SIGNAL ATTENUATION IN DECIBELS 8.0
ATTENUATION ACCURACY REFERENCE FREQUENCY 0.750 GIGAHERTZ
POWER RATING 1.5 WATTS AVERAGE
OPERATING TEMP RANGE -55.0 TO 150.0 DEG CELSIUS
BODY STYLE RECTANGULAR TERMINAL/TERMINALS ON THREE SURFACES
OVERALL LENGTH 0.650 INCHES NOMINAL
OVERALL HEIGHT 0.040 INCHES MAXIMUM
OVERALL WIDTH 0.375 INCHES NOMINAL
BODY MATERIAL ALUMINUM
TERMINAL TYPE AND QUANTITY 3 TAB, SOLDER LUG
III PRECIOUS MATERIAL GOLD
III PRECIOUS MATERIAL AND LOCATION SOLDERABLE TABS GOLD

Restrictions/Controls & Freight Information | NSN 5985-01-621-5385

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:GItem contains gold
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information