Product Details | FIXED ATTENUATOR

5985-01-619-8805 A device for reducing the strength of an alternating current signal by a fixed or predetermined amount, without causing appreciable signal distortion, by maintaining correct impedance match.

Part Alternates: BWN20W20, 5985-01-619-8805, 01-619-8805, 5985016198805, 016198805

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 2013172 01-619-8805

Cross Reference | NSN 5985-01-619-8805

Part Number Cage Code Manufacturer
BW-N20W20+ 15542 SCIENTIFIC COMPONENTS CORP DBA MINI CIRCUITS LABORATORIES

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5985-01-619-8805

Technical Data | NSN 5985-01-619-8805

Characteristic Specifications
APPLICATION DESIGN TRANSMISSION LINE
FREQUENCY RANGE 18000.0 MEGAHERTZ MAXIMUM
RF SIGNAL ATTENUATION IN DECIBELS 21.0
POWER RATING 20.0 WATTS PEAK
OPERATING TEMP RANGE -55.0 TO 100.0 DEG CELSIUS
OVERALL LENGTH 3.04 INCHES NOMINAL
OVERALL DIAMETER 1.50 INCHES NOMINAL
PART NAME ASSIGNED BY CONTROLLING AGENCY PRECISION FIXED ATTENUATOR

Restrictions/Controls & Freight Information | NSN 5985-01-619-8805

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information